Coleman / AIR-SOURCE HEAT PUMP

HH860E2S11

LX SERIES · source records, page 9

623 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity43,500–54,500BTU/h

Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 623 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19623 / 623
EER2 · BTU/Wh10–12623 / 623
HSPF2 · BTU/Wh8.1–9.5623 / 623
Cooling capacity · BTU/h43,500–54,500623 / 623
Heating capacity at 47°F / 8.3°C · BTU/h43,500–56,000623 / 623
Heating capacity at 17°F / −8.3°C · BTU/h31,800–39,000623 / 623
Heating capacity at 5°F / −15°C · BTU/h32,000–40,500623 / 623
COP at 5°F / −15°C2623 / 623
Equipment / loop typeHP - Split System623 / 623
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)623 / 623
Compressor stagingContinuously variable623 / 623
Connected capabilityNo623 / 623

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHE60D5CH2SS2Cold climate designationAHRI reference: 21845707119.008.50385002.00EPA 4639491
CTF60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 21852077619.009.00385002.00EPA 4642178
CTF60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 21852077219.009.00385002.00EPA 4642182
CTF60C5CHS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21852076819.008.50390002.00EPA 4642186
CTF60C5CHS2+JMVT17CC2N1AHRI reference: 21852076419.009.00380002.00EPA 4642190
CTF60C5CHS2+ furnace: CP9C100C20MP13AHRI reference: 21852076219.008.50385002.00EPA 4642192
CTF60C5CHS2+ furnace: TP9C100C20MP13AHRI reference: 21852075819.008.50385002.00EPA 4642196
CTF60C5CHS2+ furnace: TM9V100C20MP12AHRI reference: 21852075419.008.50385002.00EPA 4642200
CTF60C5CHS2+ furnace: TL8E100C20UH11AHRI reference: 21852075019.009.00385002.00EPA 4642204
CTF60C5CHS2+ furnace: Z8ES080C20LMPS1AHRI reference: 21852074619.009.00390002.00EPA 4642208
CTF60C5CHS2+ furnace: Z8ES080C20SMPS1AHRI reference: 21852074219.009.00390002.00EPA 4642212
CTF60C5CHS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852073819.009.00380002.00EPA 4642216
CTF60C5CHS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852073419.009.00380002.00EPA 4642220
CTF60C5CHS2+ furnace: Z8ES100C20LMPS1AHRI reference: 21852073019.009.00380002.00EPA 4642224
CTF60C5CHS2+ furnace: Z8ES100C20SMPS1AHRI reference: 21852072619.009.00380002.00EPA 4642228
CTF60C5CHS2+JMC17C2SN1AHRI reference: 21852072219.009.00380002.00EPA 4642232
CTF60C5CHS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852071819.008.50390002.00EPA 4642236
CTF60C5CHS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21852071419.008.50385002.00EPA 4642240
CTF60C5CHS2+ furnace: TM8V100C20MP12AHRI reference: 21852071019.008.50385002.00EPA 4642244
CTF60C5CHS2+ furnace: TM8V120C20MP12AHRI reference: 21852070619.008.50385002.00EPA 4642248

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.