HH860E2S11
LX SERIES · source records, page 10
623 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 623 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 623 / 623 |
| EER2 · BTU/Wh | 10–12 | 623 / 623 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 623 / 623 |
| Cooling capacity · BTU/h | 43,500–54,500 | 623 / 623 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 623 / 623 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 623 / 623 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 623 / 623 |
| COP at 5°F / −15°C | 2 | 623 / 623 |
| Equipment / loop type | HP - Split System | 623 / 623 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 623 / 623 |
| Compressor staging | Continuously variable | 623 / 623 |
| Connected capability | No | 623 / 623 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218520702 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4642252 → |
CTF60C5CHS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218520698 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4642256 → |
CTF60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218520694 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4642260 → |
CTF60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218520690 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4642264 → |
CTM60D5CJS2+JMVT20DC2N1AHRI reference: 218521020 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644552 → |
CTM60D5CJS2+JMC20D2SN1AHRI reference: 218521016 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644556 → |
CTM60D5CJS2+ furnace: CP9C120D20MP13AHRI reference: 218521010 | 19.00 | 9.00 | 40000 | 2.00 | EPA 4644558 → |
CTM60D5CJS2+ furnace: TP9C120D20MP13AHRI reference: 218521006 | 19.00 | 9.00 | 40000 | 2.00 | EPA 4644562 → |
CTM60D5CJS2+ furnace: TM9V120D20MP12AHRI reference: 218521002 | 19.00 | 9.00 | 40000 | 2.00 | EPA 4644566 → |
CTM60D5CJS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218520998 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644570 → |
CTM60D5CJS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218520994 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644574 → |
CTM60D5CHS2+JMC20D2SN1AHRI reference: 218520990 | 19.00 | 8.50 | 38000 | 2.00 | EPA 4644578 → |
CTM60D5CHS2+JMVT20DC2N1AHRI reference: 218520986 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644582 → |
CTM60D5CHS2+ furnace: CP9C120D20MP13AHRI reference: 218520984 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4644584 → |
CTM60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 218520980 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4644588 → |
CTM60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 218520976 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4644592 → |
CTM60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218520972 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644596 → |
CTM60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218520968 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644600 → |
CTM60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 218520964 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4644604 → |
CTM60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 218520960 | 19.00 | 8.50 | 40000 | 2.00 | EPA 4644608 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →