Coleman / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 30

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS2+ furnace: TM9V100C20MP12AHRI reference: 21852226818.009.00258002.00EPA 4643328 →
CTU48C5XFS2+TXV+ furnace: TL9E100C20UH11AHRI reference: 21852226418.009.00256002.00EPA 4643332 →
CTF48C5CFS2+ furnace: TL9E100C20UH11AHRI reference: 21852226018.009.00256002.00EPA 4643336 →
CTU48C5XFS2+TXV+ furnace: TL8E080C16UH11AHRI reference: 21852225618.009.00254002.00EPA 4643340 →
CTF48C5CFS2+ furnace: TL8E080C16UH11AHRI reference: 21852225218.009.00254002.00EPA 4643344 →
CTU48C5XFS2+TXV+ furnace: TM8V080C16MP12AHRI reference: 21852223218.009.00254002.00EPA 4643364 →
CTU48C5XFS2+TXV+ furnace: TM8V100C16MP12AHRI reference: 21852222818.009.00254002.00EPA 4643368 →
CTF48C5CFS2+ furnace: TM8V080C16MP12AHRI reference: 21852222418.009.00254002.00EPA 4643372 →
CTF48C5CFS2+ furnace: TM8V100C16MP12AHRI reference: 21852222018.009.00254002.00EPA 4643376 →
CTU48C5XFS2+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21852221618.009.00256002.00EPA 4643380 →
CTF48C5CFS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852221218.009.00256002.00EPA 4643384 →
CTU48C5XFS2+TXV+ furnace: TL8E100C20UH11AHRI reference: 21852219218.009.00252002.00EPA 4643404 →
CTF48C5CFS2+ furnace: TL8E100C20UH11AHRI reference: 21852218818.009.00252002.00EPA 4643408 →
CTF36C5CDS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21852216818.008.50238002.00EPA 4643428 →
CTF36C5ADS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21852216418.008.50238002.00EPA 4643432 →
CTF36C5CDS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21852215218.008.50230002.00EPA 4643444 →
CTF36C5ADS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21852214818.008.50230002.00EPA 4643448 →
CTF36C5CDS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852212418.008.50258002.00EPA 4643452 →
CTF36C5CDS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852212018.008.50258002.00EPA 4643456 →
CTF36C5ADS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852211618.008.50258002.00EPA 4643460 →