Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36C5CDS1+ furnace: Z9ET080C16SMPS1Cold climate designationAHRI reference: 216374671 | 18.00 | 8.50 | 23800 | 2.00 | EPA 4047702 → |
CTF36B5CDS1+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374712 | 18.00 | 8.50 | 24000 | 2.00 | EPA 4047713 → |
CTF36B5CDS1+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374748 | 18.00 | 8.50 | 24200 | 2.00 | EPA 4047765 → |
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374753 | 18.00 | 8.50 | 24000 | 2.00 | EPA 4047777 → |
CTF30A5ADS1+ furnace: TMLE060A12MP11AHRI reference: 216508741 | 18.00 | 8.00 | 25400 | 2.00 | EPA 4639541 → |
CTF30A5ADS1+ furnace: TM8E060A12MP11AHRI reference: 216508731 | 18.00 | 8.00 | 25400 | 2.00 | EPA 4639543 → |
CTF30A5ADS1+ furnace: TL8E060A12UH11AHRI reference: 216508722 | 18.00 | 8.00 | 25400 | 2.00 | EPA 4639546 → |
CTU48C5XFS2+TXV+ furnace: CP9C100C16MP13AHRI reference: 218522354 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643242 → |
CTU48C5XFS2+TXV+ furnace: TP9C100C16MP13AHRI reference: 218522350 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643246 → |
CTU48C5XFS2+TXV+ furnace: TM9V100C16MP12AHRI reference: 218522346 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643250 → |
CTF48C5CFS2+ furnace: CP9C100C16MP13AHRI reference: 218522344 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643252 → |
CTF48C5CFS2+ furnace: TP9C100C16MP13AHRI reference: 218522340 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643256 → |
CTF48C5CFS2+ furnace: TM9V100C16MP12AHRI reference: 218522336 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643260 → |
CTU48C5XFS2+TXV+ furnace: TL9E080C16UH11AHRI reference: 218522292 | 18.00 | 9.00 | 25400 | 2.00 | EPA 4643304 → |
CTF48C5CFS2+ furnace: TL9E080C16UH11AHRI reference: 218522288 | 18.00 | 9.00 | 25400 | 2.00 | EPA 4643308 → |
CTU48C5XFS2+TXV+ furnace: CP9C100C20MP13AHRI reference: 218522286 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643310 → |
CTU48C5XFS2+TXV+ furnace: TP9C100C20MP13AHRI reference: 218522282 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643314 → |
CTU48C5XFS2+TXV+ furnace: TM9V100C20MP12AHRI reference: 218522278 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643318 → |
CTF48C5CFS2+ furnace: CP9C100C20MP13AHRI reference: 218522276 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643320 → |
CTF48C5CFS2+ furnace: TP9C100C20MP13AHRI reference: 218522272 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643324 → |