Coleman / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 21

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS2+JME12C2SN2AHRI reference: 21863748419.009.00252002.00EPA 4664023 →
CTF48C5AFS2+JME12C2SN2AHRI reference: 21863747819.009.00252002.00EPA 4664029 →
CTM36C5CDS2+JME12C2SN2AHRI reference: 21863747219.009.00256002.00EPA 4664035 →
CTM36C5ADS2+JME12C2SN2AHRI reference: 21863746619.009.00256002.00EPA 4664041 →
CTU48C5XFS2+JME16C2SN2+TXVAHRI reference: 21863746019.009.00252002.00EPA 4664047 →
CTF48C5CFS2+JME16C2SN2AHRI reference: 21863745419.009.00252002.00EPA 4664052 →
CTF48C5AFS2+JME16C2SN2AHRI reference: 21863744819.009.00252002.00EPA 4664056 →
CTM36B5CDS1+JMC12B2SN1Cold climate designationAHRI reference: 21439767918.009.00248002.00EPA 3437710 →
CTF36C5CDS1+ furnace: Z8ES080C16SMPS1Cold climate designationAHRI reference: 21458467618.008.50254002.00EPA 3438109 →
CTM36C5CDS1+ furnace: Z8ES080C16SMPS1Cold climate designationAHRI reference: 21458470618.008.50254002.00EPA 3438117 →
CTM36C5CDS1+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 21458471118.008.50260002.00EPA 3438122 →
CTM36C5CDS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 21458474118.008.50258002.00EPA 3438183 →
CTF36C5CDS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 21458467118.008.50258002.00EPA 3438202 →
CTF36B5CDS1+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21458459118.008.50248002.00EPA 3438257 →
CTF36C5CDS1+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 21458455618.008.50260002.00EPA 3438268 →
CTF36B5CDS1+ furnace: Z8ES100B12SMPS1Cold climate designationAHRI reference: 21458462118.008.50250002.00EPA 3438307 →
CTM36B5CDS1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 21439682018.008.50250002.00EPA 3558512 →
CTM36B5CDS1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 21439682518.008.50250002.00EPA 3558517 →
CTM36B5CDS1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 21439848618.008.50256002.00EPA 3558761 →
CTU36B5XDS1+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21480776118.008.50248002.00EPA 3559582 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →