Coleman / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 20

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5AFS2+ furnace: Z8ES100C20LMPS1AHRI reference: 21858614019.009.00254002.00EPA 4650774
CTM48C5AFS2+ furnace: Z8ES100C20SMPS1AHRI reference: 21858612419.009.00254002.00EPA 4650782
CTM48C5AFS2+ furnace: TL8E100C20UH11AHRI reference: 21858611219.009.00254002.00EPA 4650786
CTM48C5AFS2+ furnace: TL8E080C16UH11AHRI reference: 21858610219.009.00256002.00EPA 4650790
CTM48C5AFS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21858607919.009.50234002.00EPA 4650798
CTM48C5AFS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21858606819.009.50242002.00EPA 4650802
CTF36C5CDS2+JME16C2SN2AHRI reference: 21863757319.009.00256002.00EPA 4663940
CTF36C5ADS2+JME16C2SN2AHRI reference: 21863756719.009.00256002.00EPA 4663946
CTM36C5CDS2+JME16C2SN2AHRI reference: 21863756219.009.00256002.00EPA 4663951
CTM36C5ADS2+JME16C2SN2AHRI reference: 21863755519.009.00256002.00EPA 4663958
CTM48C5CFS2+JME12C2SN2AHRI reference: 21863754919.009.00252002.00EPA 4663964
CTM48C5AFS2+JME12C2SN2AHRI reference: 21863754419.009.00252002.00EPA 4663969
CTF36C5CDS2+JME12C2SN2AHRI reference: 21863753819.009.00256002.00EPA 4663975
CTF36C5ADS2+JME12C2SN2AHRI reference: 21863753119.009.00256002.00EPA 4663982
CTM48C5CFS2+JME16C2SN2AHRI reference: 21863752419.009.00252002.00EPA 4663989
CTM48C5AFS2+JME16C2SN2AHRI reference: 21863751719.009.00252002.00EPA 4663995
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 21863751019.009.00258002.00EPA 4664000
CTF36B5CDS2+JME12B2SN2AHRI reference: 21863750319.009.00258002.00EPA 4664006
CTF36B5ADS2+JME12B2SN2AHRI reference: 21863749719.009.00258002.00EPA 4664011
CTU48C5XFS2+JME12C2SN2+TXVAHRI reference: 21863749019.009.00252002.00EPA 4664017