Each efficiency range summarizes published EPA records for XH936E2C11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 149 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 149 / 149 |
| EER2 · BTU/Wh | 10–13 | 149 / 149 |
| HSPF2 · BTU/Wh | 9–9.5 | 149 / 149 |
| Cooling capacity · BTU/h | 23,000–35,600 | 149 / 149 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–35,000 | 149 / 149 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,600–31,400 | 149 / 149 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,000–33,600 | 149 / 149 |
| COP at 5°F / −15°C | 2 | 149 / 149 |
| Equipment / loop type | HP - Split System | 149 / 149 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 149 / 149 |
| Compressor staging | Continuously variable | 149 / 149 |
| Connected capability | No | 149 / 149 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36C5ADS2+CC+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 218586937 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650366 → |
CTF36B5ADS2+CC+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 218586858 | 18.00 | 9.50 | 33200 | 2.00 | EPA 4650405 → |
CTF36B5ADS2+CC+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 218586843 | 18.00 | 9.50 | 33200 | 2.00 | EPA 4650413 → |
CTF36C5ADS2+CC+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 218586827 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650421 → |
CTF36C5ADS2+CC+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 218586811 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650429 → |
CTM36C5ADS2+CC+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 218586786 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650442 → |
CTM36C5ADS2+CC+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 218586769 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650450 → |
CTM36C5ADS2+CC+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 218586610 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650529 → |
CTM36C5ADS2+CC+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 218586594 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650537 → |
CTM36C5ADS2+CC+ furnace: TPLC120C20MP13Cold climate designationAHRI reference: 218586460 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650611 → |
CTM36C5ADS2+CC+ furnace: TPLC100C20MP13Cold climate designationAHRI reference: 218586445 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650619 → |
CTM36C5ADS2+CC+ furnace: TM8V100C20MP12Cold climate designationAHRI reference: 218586429 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650627 → |
CTM36C5ADS2+CC+ furnace: TM8V120C20MP12Cold climate designationAHRI reference: 218586415 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650635 → |
CTF36B5ADS2+CC+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 218586390 | 18.00 | 9.50 | 33400 | 2.00 | EPA 4650647 → |
CTF36B5ADS2+CC+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 218586372 | 18.00 | 9.50 | 33400 | 2.00 | EPA 4650656 → |
CTF36C5ADS2+CC+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 218586355 | 18.00 | 9.50 | 32400 | 2.00 | EPA 4650664 → |
CTM36C5ADS2+CC+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 218586340 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650672 → |
CTM36C5ADS2+CC+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 218586323 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650680 → |
CTF36B5ADS1+CC+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218027668 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4570232 → |
CTM36B5ADS1+CC+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 218027409 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4570275 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.