XH936E2C11
LX SERIES · source records, page 6
149 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH936E2C11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 149 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 149 / 149 |
| EER2 · BTU/Wh | 10–13 | 149 / 149 |
| HSPF2 · BTU/Wh | 9–9.5 | 149 / 149 |
| Cooling capacity · BTU/h | 23,000–35,600 | 149 / 149 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–35,000 | 149 / 149 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,600–31,400 | 149 / 149 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,000–33,600 | 149 / 149 |
| COP at 5°F / −15°C | 2 | 149 / 149 |
| Equipment / loop type | HP - Split System | 149 / 149 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 149 / 149 |
| Compressor staging | Continuously variable | 149 / 149 |
| Connected capability | No | 149 / 149 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36B5ADS2+CC+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 218588027 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4649927 → |
CTM36B5ADS2+CC+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 218588015 | 18.00 | 9.50 | 33600 | 2.00 | EPA 4649931 → |
CTF36C5ADS2+CC+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 218588003 | 18.00 | 9.50 | 32400 | 2.00 | EPA 4649935 → |
CTF36C5ADS2+CC+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 218587990 | 18.00 | 9.50 | 32400 | 2.00 | EPA 4649939 → |
CTM36C5ADS2+CC+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 218587979 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4649943 → |
CTF36C5ADS2+CC+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 218587800 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650005 → |
CTF36C5ADS2+CC+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 218587787 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650009 → |
CTF36C5ADS2+CC+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 218587768 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650015 → |
CTF36C5ADS2+CC+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 218587754 | 18.00 | 9.50 | 33000 | 2.00 | EPA 4650019 → |
CTM36B5ADS2+CC+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 218587742 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650023 → |
CTM36C5ADS2+CC+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 218587725 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650029 → |
CTM36C5ADS2+CC+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 218587713 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650033 → |
CTF36C5ADS2+JMC16C2SN1+CCCold climate designationAHRI reference: 218587575 | 18.00 | 9.00 | 32200 | 2.00 | EPA 4650081 → |
CTF36C5ADS2+CC+ furnace: TM8V100C20MP12Cold climate designationAHRI reference: 218587482 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650113 → |
CTF36C5ADS2+CC+ furnace: TM8V120C20MP12Cold climate designationAHRI reference: 218587470 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650117 → |
CTF36B5ADS2+CC+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 218587459 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650121 → |
CTM36C5ADS2+CC+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 218587448 | 18.00 | 9.50 | 32400 | 2.00 | EPA 4650125 → |
CTM36C5ADS2+CC+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 218587186 | 18.00 | 9.50 | 32600 | 2.00 | EPA 4650241 → |
CTF36C5ADS2+CC+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 218587107 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650281 → |
CTF36C5ADS2+CC+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 218587090 | 18.00 | 9.50 | 32800 | 2.00 | EPA 4650289 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →