CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 12

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17454 / 454
EER2 · BTU/Wh11–12454 / 454
HSPF2 · BTU/Wh8–8.5454 / 454
Cooling capacity · BTU/h32,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800454 / 454
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800454 / 454
COP at 5°F / −15°C2–2.5454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)454 / 454
Compressor stagingTwo-stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS1+ furnace: TP9C080C16MP13AHRI reference: 21799404116.008.10182002.00EPA 4514690 →
CTU48C5XFS1+TXV+ furnace: TM9V080C16MP12AHRI reference: 21799404816.008.10182002.00EPA 4514698 →
CTU48C5XFS1+TXV+ furnace: TP9C080C16MP13AHRI reference: 21799405316.008.10182002.00EPA 4514702 →
CTF48C5CFS1+ furnace: TM9V100C16MP12AHRI reference: 21799395216.008.10186002.00EPA 4514963 →
CTF48C5CFS1+ furnace: TP9C100C16MP13AHRI reference: 21799395716.008.10186002.00EPA 4514969 →
CTU48C5XFS1+TXV+ furnace: TM9V100C16MP12AHRI reference: 21799396416.008.10186002.00EPA 4514975 →
CTU48C5XFS1+TXV+ furnace: TP9C100C16MP13AHRI reference: 21799396916.008.10186002.00EPA 4514980 →
CTU48C5XFS1+TXV+ furnace: TP9C100C20MP13AHRI reference: 21799401716.008.10186002.00EPA 4518348 →
JHE36B5CD2SS2AHRI reference: 21845721216.008.00180002.00EPA 4622471 →
JHE36C5CD2SS2AHRI reference: 21845720616.008.10185002.36EPA 4622477 →
CTF36B5CDS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21852727416.008.10185002.34EPA 4645815 →
CTF48C5CFS2+ furnace: TM9V100C16MP12AHRI reference: 21852797016.008.10186002.00EPA 4646222 →
CTU48C5XFS2+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21852796616.008.10191002.46EPA 4646226 →
CTF48C5CFS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21852796216.008.10191002.46EPA 4646230 →
CTU48C5XFS2+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21852795816.008.10192002.44EPA 4646234 →
CTF48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21852795416.008.10192002.44EPA 4646238 →
CTU48C5XFS2+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 21852795016.008.10192002.44EPA 4646242 →
CTF48C5CFS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21852794616.008.10192002.44EPA 4646246 →
CTU48C5XFS2+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 21852794216.008.10192002.44EPA 4646250 →
CTF48C5CFS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21852793816.008.10192002.44EPA 4646254 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →