CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 11

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17454 / 454
EER2 · BTU/Wh11–12454 / 454
HSPF2 · BTU/Wh8–8.5454 / 454
Cooling capacity · BTU/h32,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800454 / 454
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800454 / 454
COP at 5°F / −15°C2–2.5454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)454 / 454
Compressor stagingTwo-stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744522016.008.10187002.36EPA 4045219 →
CTM36C5CDS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744522116.008.10186002.38EPA 4045220 →
CTF36C5CDS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744522216.008.10187002.36EPA 4045221 →
CTF36C5CDS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744522316.008.10187002.36EPA 4045222 →
CTF36B5CDS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21744522516.008.10185002.34EPA 4045224 →
CTU36B5XDS1+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21744522616.008.10185002.34EPA 4045225 →
CTM36C5CDS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744522716.008.10187002.36EPA 4045226 →
CTF36C5CDS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744522816.008.10185002.36EPA 4045227 →
CTM36C5CDS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744522916.008.10186002.36EPA 4045228 →
JHE36B5CD2SS1AHRI reference: 21701673416.008.00180002.00EPA 4498111 →
CTM48C5CFS1+ furnace: TM9V080C16MP12AHRI reference: 21799402416.008.10184002.00EPA 4514628 →
CTM48C5CFS1+ furnace: TP9C080C16MP13AHRI reference: 21799402916.008.10184002.00EPA 4514633 →
CTM48C5CFS1+ furnace: TM9V100C16MP12AHRI reference: 21799397616.008.10186002.00EPA 4514643 →
CTM48C5CFS1+ furnace: TP9C100C16MP13AHRI reference: 21799398116.008.10186002.00EPA 4514649 →
CTM48C5CFS1+ furnace: TM9V100C20MP12AHRI reference: 21799398816.008.10186002.00EPA 4514656 →
CTM48C5CFS1+ furnace: TP9C100C20MP13AHRI reference: 21799399316.008.10186002.00EPA 4514662 →
CTF48C5CFS1+ furnace: TM9V100C20MP12AHRI reference: 21799400016.008.10186002.00EPA 4514668 →
CTF48C5CFS1+ furnace: TP9C100C20MP13AHRI reference: 21799400516.008.10186002.00EPA 4514673 →
CTU48C5XFS1+TXV+ furnace: TM9V100C20MP12AHRI reference: 21799401216.008.10186002.00EPA 4514680 →
CTF48C5CFS1+ furnace: TM9V080C16MP12AHRI reference: 21799403616.008.10182002.00EPA 4514685 →