CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH630E2S11

LX SERIES · source records, page 2

219 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,400–31,000BTU/h

Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 219 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17219 / 219
EER2 · BTU/Wh11–13219 / 219
HSPF2 · BTU/Wh8–8.1219 / 219
Cooling capacity · BTU/h28,400–31,000219 / 219
Heating capacity at 47°F / 8.3°C · BTU/h28,800–30,000219 / 219
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,200219 / 219
Heating capacity at 5°F / −15°C · BTU/h15,000–16,400219 / 219
COP at 5°F / −15°C2–2.4219 / 219
Equipment / loop typeHP - Split System219 / 219
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)219 / 219
Compressor stagingTwo-stage219 / 219
Connected capabilityNo219 / 219

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5ADS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21853053217.008.10152002.40EPA 4648346
CTF36C5ADS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21853052817.008.10152002.40EPA 4648350
CTF36C5ADS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21853050617.008.10154002.36EPA 4648372
CTF36C5ADS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21853050217.008.10154002.36EPA 4648376
CTF36C5ADS2+ furnace: Z8ET080C16LMPS1AHRI reference: 21853049817.008.10152002.40EPA 4648380
CTM36C5ADS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21853041817.008.10154002.36EPA 4648448
CTM36C5ADS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21853041417.008.10154002.36EPA 4648452
CTM36C5ADS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21853040217.008.10152002.40EPA 4648464
CTM36C5ADS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21853039817.008.10152002.40EPA 4648468
CTM36C5ADS2+ furnace: Z8ET080C16LMPS1AHRI reference: 21853039417.008.10152002.40EPA 4648472
CTU36B5XDS2+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 21853034617.008.10156002.30EPA 4648520
CTF36B5ADS2+ furnace: Z8ET080B12LMPS1AHRI reference: 21853034217.008.10156002.30EPA 4648524
CTU36B5XDS2+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 21853026817.008.10154002.34EPA 4648598
CTU36B5XDS2+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21853026417.008.10154002.34EPA 4648602
CTF36B5ADS2+ furnace: Z8ES080B12LMPS1AHRI reference: 21853025817.008.10154002.34EPA 4648608
CTF36B5ADS2+ furnace: Z8ES080B12SMPS1AHRI reference: 21853025417.008.10154002.34EPA 4648612
JHE30B5AD2SS1AHRI reference: 21841667416.008.00154002.36EPA 4608498
CTM36C5ADS1+ furnace: TM9V100C16MP12AHRI reference: 21841837216.008.10156002.32EPA 4608528
CTM36B5ADS1+ furnace: Z9ES080B12SMPS1AHRI reference: 21841832016.008.10158002.26EPA 4608544
CTU36B5XDS1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21841829816.008.10152002.36EPA 4608566

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →