XH630E2S11
LX SERIES
219 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 219 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 219 / 219 |
| EER2 · BTU/Wh | 11–13 | 219 / 219 |
| HSPF2 · BTU/Wh | 8–8.1 | 219 / 219 |
| Cooling capacity · BTU/h | 28,400–31,000 | 219 / 219 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 28,800–30,000 | 219 / 219 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,800–20,200 | 219 / 219 |
| Heating capacity at 5°F / −15°C · BTU/h | 15,000–16,400 | 219 / 219 |
| COP at 5°F / −15°C | 2–2.4 | 219 / 219 |
| Equipment / loop type | HP - Split System | 219 / 219 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 219 / 219 |
| Compressor staging | Two-stage | 219 / 219 |
| Connected capability | No | 219 / 219 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36C5ADS1+ furnace: Z8ET080C16LMPS1AHRI reference: 218418326 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608538 → |
CTM36C5ADS1+ furnace: Z8ES100C16LMPS1AHRI reference: 218418314 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608550 → |
CTM36C5ADS1+ furnace: Z8ES100C16SMPS1AHRI reference: 218418310 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608554 → |
CTU36B5XDS1+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 218418212 | 17.00 | 8.10 | 15600 | 2.30 | EPA 4608652 → |
CTF36B5ADS1+ furnace: Z8ET080B12LMPS1AHRI reference: 218418208 | 17.00 | 8.10 | 15600 | 2.30 | EPA 4608656 → |
CTM36C5ADS1+ furnace: Z8ES080C16LMPS1AHRI reference: 218418046 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608818 → |
CTM36C5ADS1+ furnace: Z8ES080C16SMPS1AHRI reference: 218418042 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608822 → |
CTF36C5ADS1+ furnace: Z8ET080C16LMPS1AHRI reference: 218418038 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608826 → |
CTU36B5XDS1+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 218418032 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608832 → |
CTU36B5XDS1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 218418028 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608836 → |
CTF36B5ADS1+ furnace: Z8ES080B12LMPS1AHRI reference: 218418022 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608842 → |
CTF36B5ADS1+ furnace: Z8ES080B12SMPS1AHRI reference: 218418018 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608846 → |
CTF36C5ADS1+ furnace: Z8ES100C16LMPS1AHRI reference: 218418012 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608852 → |
CTF36C5ADS1+ furnace: Z8ES100C16SMPS1AHRI reference: 218418008 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608856 → |
JHE36B5AD2SS1AHRI reference: 218418002 | 17.00 | 8.10 | 15400 | 2.00 | EPA 4608862 → |
JHE36C5AD2SS1AHRI reference: 218417996 | 17.00 | 8.10 | 15200 | 2.00 | EPA 4608868 → |
JHC36B5AD2SS1AHRI reference: 218417992 | 17.00 | 8.10 | 15400 | 2.00 | EPA 4608872 → |
JHC36C5AD2SS1AHRI reference: 218417988 | 17.00 | 8.10 | 15000 | 2.00 | EPA 4608876 → |
CTF36C5ADS1+ furnace: Z8ES080C16LMPS1AHRI reference: 218418464 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4609546 → |
CTF36C5ADS1+ furnace: Z8ES080C16SMPS1AHRI reference: 218418460 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4609550 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.