CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH618E2S11

LX SERIES · source records, page 13

272 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,000–18,300BTU/h

Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 272 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16272 / 272
EER2 · BTU/Wh12–12.5272 / 272
HSPF2 · BTU/Wh7.8–8272 / 272
Cooling capacity · BTU/h17,000–18,300272 / 272
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000272 / 272
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300272 / 272
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100272 / 272
COP at 5°F / −15°C2.26–2.34272 / 272
Equipment / loop typeHP - Split System272 / 272
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)272 / 272
Compressor stagingSingle stage272 / 272
Connected capabilityNo272 / 272

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF24A5ABS2+ furnace: Z8ES060A12LMPS1AHRI reference: 21853063015.207.8088002.28EPA 4648278 →
CTF24A5ABS2+ furnace: Z8ES060A12SMPS1AHRI reference: 21853062615.207.8088002.28EPA 4648282 →
CTM30B5ACS2+ furnace: Z8ES080B12LMPS1AHRI reference: 21853130215.207.8088002.30EPA 4649682 →
CTM30B5ACS2+ furnace: Z8ES080B12SMPS1AHRI reference: 21853129815.207.8088002.30EPA 4649686 →
CTM30B5ACS2+ furnace: Z9ES080B12SMPS1AHRI reference: 21853129015.207.8091002.28EPA 4649690 →
CTM30B5ACS2+ furnace: TMLE100B12MP11AHRI reference: 21853128615.207.8091002.28EPA 4649694 →
CTM30B5ACS2+ furnace: TM8E100B12MP11AHRI reference: 21853128215.207.8091002.28EPA 4649698 →
CTM30B5ACS2+ furnace: Z9ET080B12SMPS1AHRI reference: 21853127015.207.8091002.28EPA 4649702 →
CTM30B5ACS2+ furnace: Z8ES100B12LMPS1AHRI reference: 21853125615.207.8088002.30EPA 4649706 →
CTM30B5ACS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21853125215.207.8088002.30EPA 4649710 →
CTM30B5ACS2+ furnace: Z8ET080B12LMPS1AHRI reference: 21853124815.207.8088002.30EPA 4649714 →
CTM30B5ACS2+ furnace: TP9C080B12MP13AHRI reference: 21853124215.207.8090002.28EPA 4649720 →
CTM30B5ACS2+ furnace: TM9V080B12MP12AHRI reference: 21853123815.207.8090002.28EPA 4649724 →
CTM30B5ACS2+ furnace: TMLE080B12MP11AHRI reference: 21853123415.207.8091002.28EPA 4649728 →
CTM30B5ACS2+ furnace: TM8E080B12MP11AHRI reference: 21853123015.207.8091002.28EPA 4649732 →
CTM24B5ABS2+JMC12B2SN1AHRI reference: 21853120415.207.8089002.32EPA 4649748 →
CTM24B5ABS2+ furnace: Z8ES080B12LMPS1AHRI reference: 21853119615.207.8088002.28EPA 4649752 →
CTM24B5ABS2+ furnace: Z8ES080B12SMPS1AHRI reference: 21853119215.207.8088002.28EPA 4649756 →
CTM24B5ABS2+ furnace: TMLE100B12MP11AHRI reference: 21853118815.207.8091002.26EPA 4649760 →
CTM24B5ABS2+ furnace: TM8E100B12MP11AHRI reference: 21853118415.207.8091002.26EPA 4649764 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →