CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH618E2S11

LX SERIES · source records, page 12

272 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,000–18,300BTU/h

Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 272 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16272 / 272
EER2 · BTU/Wh12–12.5272 / 272
HSPF2 · BTU/Wh7.8–8272 / 272
Cooling capacity · BTU/h17,000–18,300272 / 272
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000272 / 272
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300272 / 272
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100272 / 272
COP at 5°F / −15°C2.26–2.34272 / 272
Equipment / loop typeHP - Split System272 / 272
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)272 / 272
Compressor stagingSingle stage272 / 272
Connected capabilityNo272 / 272

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU24A5XBS2+TXV+ furnace: TMLE040A12MP11AHRI reference: 21853073815.207.8090002.26EPA 4648194
CTU24A5XBS2+TXV+ furnace: TM8E040A12MP11AHRI reference: 21853073415.207.8090002.26EPA 4648198
CTF24A5ABS2+ furnace: TMLE040A12MP11AHRI reference: 21853073015.207.8090002.26EPA 4648202
CTF24A5ABS2+ furnace: TM8E040A12MP11AHRI reference: 21853072615.207.8090002.26EPA 4648206
CTU24A5XBS2+TXV+ furnace: TPLC060A12MP13AHRI reference: 21853072015.207.8089002.26EPA 4648212
CTU24A5XBS2+TXV+ furnace: TMLV060A12MP12AHRI reference: 21853071615.207.8089002.26EPA 4648216
CTU24A5XBS2+TXV+ furnace: TM8V060A12MP12AHRI reference: 21853071215.207.8089002.26EPA 4648220
CTF24A5ABS2+ furnace: TPLC060A12MP13AHRI reference: 21853070615.207.8089002.26EPA 4648226
CTF24A5ABS2+ furnace: TMLV060A12MP12AHRI reference: 21853070215.207.8089002.26EPA 4648230
CTF24A5ABS2+ furnace: TM8V060A12MP12AHRI reference: 21853069815.207.8089002.26EPA 4648234
CTU24A5XBS2+TXV+ furnace: Z8ES040A12LMPS1AHRI reference: 21853068615.207.8088002.28EPA 4648238
CTU24A5XBS2+TXV+ furnace: Z8ES040A12SMPS1AHRI reference: 21853068215.207.8088002.28EPA 4648242
CTF24A5ABS2+ furnace: Z8ES040A12LMPS1AHRI reference: 21853067815.207.8088002.28EPA 4648246
CTF24A5ABS2+ furnace: Z8ES040A12SMPS1AHRI reference: 21853067415.207.8088002.28EPA 4648250
CTU24A5XBS2+TXV+ furnace: TMLE060A12MP11AHRI reference: 21853067015.207.8090002.26EPA 4648254
CTU24A5XBS2+TXV+ furnace: TM8E060A12MP11AHRI reference: 21853066615.207.8090002.26EPA 4648258
CTF24A5ABS2+ furnace: TMLE060A12MP11AHRI reference: 21853066215.207.8090002.26EPA 4648262
CTF24A5ABS2+ furnace: TM8E060A12MP11AHRI reference: 21853065815.207.8090002.26EPA 4648266
CTU24A5XBS2+TXV+ furnace: Z8ES060A12LMPS1AHRI reference: 21853063815.207.8088002.28EPA 4648270
CTU24A5XBS2+TXV+ furnace: Z8ES060A12SMPS1AHRI reference: 21853063415.207.8088002.28EPA 4648274

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →