XH548E2S11
LX SERIES · source records, page 2
359 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 359 / 359 |
| EER2 · BTU/Wh | 11–12 | 359 / 359 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 359 / 359 |
| Cooling capacity · BTU/h | 44,500–48,000 | 359 / 359 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 359 / 359 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 359 / 359 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 359 / 359 |
| COP at 5°F / −15°C | 2.1–2.42 | 359 / 359 |
| Equipment / loop type | HP - Split System | 359 / 359 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 359 / 359 |
| Compressor staging | Two-stage | 359 / 359 |
| Connected capability | No | 359 / 359 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 214428447 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559031 → |
CTM60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 214428464 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3559035 → |
CTF60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 214428682 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3559045 → |
JHC48D5CG2SS1AHRI reference: 214428763 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3559076 → |
CTF60C5CHS1+ furnace: TM8E080C20MP11AHRI reference: 214429012 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559086 → |
CTM60C5CHS1+ furnace: TM8Y120C20MP11AHRI reference: 214429145 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559096 → |
CTM60C5CHS1+ furnace: TM8Y100C20MP11AHRI reference: 214429150 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559100 → |
JHC60C5CH2SS1AHRI reference: 214429312 | 15.20 | 8.10 | 26600 | 2.38 | EPA 3559108 → |
JSC48D5CG2SS1AHRI reference: 214833534 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3560533 → |
JSE48D5CG2SS1AHRI reference: 214833539 | 15.20 | 7.80 | 24600 | 2.26 | EPA 3560538 → |
JHE48C5CG2SS1AHRI reference: 214424704 | 15.20 | 7.80 | 24800 | 2.10 | EPA 3627812 → |
CTF60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 215743096 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653185 → |
CTF60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 215743123 | 15.20 | 7.80 | 26200 | 2.38 | EPA 3653194 → |
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 215743128 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653196 → |
CTM60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 216437824 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815058 → |
CTM60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 216437829 | 15.20 | 7.80 | 26200 | 2.34 | EPA 3815063 → |
CTM60C5CHS1+ furnace: Z8ET080C16LMPS1AHRI reference: 216437834 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815068 → |
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 216437839 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3815073 → |
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 216437844 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815078 → |
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 216437849 | 15.20 | 8.00 | 25800 | 2.38 | EPA 3815083 → |