CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 2

359 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16359 / 359
EER2 · BTU/Wh11–12359 / 359
HSPF2 · BTU/Wh7.8–8.1359 / 359
Cooling capacity · BTU/h44,500–48,000359 / 359
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000359 / 359
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400359 / 359
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200359 / 359
COP at 5°F / −15°C2.1–2.42359 / 359
Equipment / loop typeHP - Split System359 / 359
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)359 / 359
Compressor stagingTwo-stage359 / 359
Connected capabilityNo359 / 359

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 21442844715.207.80262002.36EPA 3559031
CTM60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 21442846415.207.80258002.36EPA 3559035
CTF60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 21442868215.207.80258002.36EPA 3559045
JHC48D5CG2SS1AHRI reference: 21442876315.207.80248002.26EPA 3559076
CTF60C5CHS1+ furnace: TM8E080C20MP11AHRI reference: 21442901215.207.80262002.36EPA 3559086
CTM60C5CHS1+ furnace: TM8Y120C20MP11AHRI reference: 21442914515.207.80262002.36EPA 3559096
CTM60C5CHS1+ furnace: TM8Y100C20MP11AHRI reference: 21442915015.207.80262002.36EPA 3559100
JHC60C5CH2SS1AHRI reference: 21442931215.208.10266002.38EPA 3559108
JSC48D5CG2SS1AHRI reference: 21483353415.207.80248002.26EPA 3560533
JSE48D5CG2SS1AHRI reference: 21483353915.207.80246002.26EPA 3560538
JHE48C5CG2SS1AHRI reference: 21442470415.207.80248002.10EPA 3627812
CTF60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21574309615.207.80260002.40EPA 3653185
CTF60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21574312315.207.80262002.38EPA 3653194
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21574312815.207.80260002.40EPA 3653196
CTM60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21643782415.208.00260002.40EPA 3815058
CTM60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21643782915.207.80262002.34EPA 3815063
CTM60C5CHS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21643783415.208.00260002.40EPA 3815068
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21643783915.208.10262002.40EPA 3815073
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21643784415.208.00260002.40EPA 3815078
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21643784915.208.00258002.38EPA 3815083