XH548E2S11
LX SERIES
359 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 359 / 359 |
| EER2 · BTU/Wh | 11–12 | 359 / 359 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 359 / 359 |
| Cooling capacity · BTU/h | 44,500–48,000 | 359 / 359 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 359 / 359 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 359 / 359 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 359 / 359 |
| COP at 5°F / −15°C | 2.1–2.42 | 359 / 359 |
| Equipment / loop type | HP - Split System | 359 / 359 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 359 / 359 |
| Compressor staging | Two-stage | 359 / 359 |
| Connected capability | No | 359 / 359 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217444830 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4571179 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217444828 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4571181 → |
CTM60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217444827 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4571182 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217444825 | 16.00 | 7.80 | 26000 | 2.42 | EPA 4571184 → |
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217444824 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4571185 → |
CTM60C5CHS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218517965 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4641598 → |
CTM60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218517961 | 16.00 | 7.80 | 26000 | 2.42 | EPA 4641602 → |
CTM60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218517957 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4641606 → |
CTM60C5CHS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218517953 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4641610 → |
CTF60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218517287 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4642074 → |
JHE48D5CG2SS1AHRI reference: 214427356 | 15.20 | 7.80 | 24600 | 2.26 | EPA 3558480 → |
JHE60C5CH2SS1AHRI reference: 214427402 | 15.20 | 8.10 | 26400 | 2.40 | EPA 3558559 → |
CTF60C5CHS1+ furnace: TM8Y120C20MP11AHRI reference: 214428051 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3558895 → |
CTM60C5CHS1+ furnace: TM8E100C20MP11AHRI reference: 214428061 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3558904 → |
CTM60C5CHS1+ furnace: TM8E120C20MP11AHRI reference: 214428071 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3558940 → |
CTM60D5CHS1+ furnace: TM8E130D20MP11AHRI reference: 214428214 | 15.20 | 7.80 | 27200 | 2.32 | EPA 3558949 → |
CTM60D5CHS1+ furnace: TMLE130D20MP11AHRI reference: 214428219 | 15.20 | 7.80 | 27200 | 2.32 | EPA 3558954 → |
JHC60D5CH2SS1AHRI reference: 214428292 | 15.20 | 8.10 | 26400 | 2.42 | EPA 3558958 → |
JHE60D5CH2SS1AHRI reference: 214428297 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3559021 → |
CTM60C5CHS1+ furnace: TM8E080C20MP11AHRI reference: 214428442 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559026 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →