CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 6

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035543015.208.10308002.02EPA 4048718 →
XAHD60HBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035543615.208.10308002.02EPA 4048725 →
XAFD60JBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21035228415.208.10312002.18EPA 4048739 →
XAFC60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035545615.208.10314002.22EPA 4048743 →
XAHC60HXXN1+TXV+ furnace: TM8V100C20MP12AHRI reference: 21035684415.208.10308002.02EPA 4048750 →
XAHC60HXXN1+TXV+ furnace: TMLV120C20MP12AHRI reference: 21035684815.208.10308002.02EPA 4048755 →
XAFC60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035546215.208.10314002.22EPA 4048768 →
XAFC60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035348615.208.10310002.24EPA 4048783 →
XAFC60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035349215.208.10310002.24EPA 4048790 →
XAFD60HXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21035233015.208.10312002.18EPA 4048799 →
XAFD60HBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21035233615.208.10312002.18EPA 4048805 →
XAHC60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035236815.208.10308002.02EPA 4048827 →
XAHC60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035237415.208.10308002.02EPA 4048834 →
XAHC60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035682615.208.10308002.02EPA 4048844 →
XAHC60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035683215.208.10308002.02EPA 4048849 →
XAHC60HXXN1+TXV+ furnace: TM8V120C20MP12AHRI reference: 21035684015.208.10308002.02EPA 4048856 →
XAFD60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035238015.208.10312002.20EPA 4048857 →
XAFD60HBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035238615.208.10312002.20EPA 4048863 →
XAFD60JXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035528015.208.10314002.22EPA 4048890 →
XAFD60JBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035528615.208.10314002.22EPA 4048896 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →