CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 5

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60HBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21241446115.207.80318002.34EPA 3560545 →
XAFC60HBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 21241441615.207.80314002.36EPA 3560554 →
JHETC60HBCS2N1AHRI reference: 21033650515.207.80306002.22EPA 3984222 →
XAHD60HBCN1+JMVT20DC2N1AHRI reference: 21034621615.208.10294002.06EPA 3985857 →
XAFD60JBCN1+ furnace: TM9V120D20MP12AHRI reference: 21035230015.208.10308002.24EPA 3986056 →
XAFD60JBCN1+ furnace: TP9C120D20MP13AHRI reference: 21035230415.208.10308002.24EPA 3986062 →
XAFD60JBCN1+ furnace: TL8E100C20UH11AHRI reference: 21035232615.208.10310002.28EPA 3986068 →
XAHD60JBCN1+JMVT20DC2N1AHRI reference: 21035886615.208.10292002.02EPA 3988952 →
XAFC60HBCN1+ furnace: TL8E100C20UH11AHRI reference: 21035899015.208.10310002.28EPA 3988960 →
XAHC60HBCN1+ furnace: TL8E100C20UH11AHRI reference: 21035693015.207.80292002.00EPA 3989040 →
XAHD60JBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21241480115.208.10312002.36EPA 3990722 →
XAFD60HBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21241404215.207.80316002.34EPA 3990842 →
XAFD60HBCN1+ furnace: Z9ES120D20SMPS1AHRI reference: 21464793415.207.80316002.34EPA 3992322 →
XAHD60JBCN1+ furnace: Z9ES120D20SMPS1AHRI reference: 21464794115.208.10314002.32EPA 3992327 →
XAFC60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035047415.208.10308002.24EPA 4048523 →
XAFC60HBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035048015.208.10308002.24EPA 4048554 →
XAFD60JXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21035227815.208.10312002.18EPA 4048648 →
XAFD60JXXN1+TXV+ furnace: TM9E120D20MP12AHRI reference: 21035231015.208.10314002.20EPA 4048698 →
XAFD60JBCN1+ furnace: TM9E120D20MP12AHRI reference: 21035231615.208.10314002.20EPA 4048704 →
XAFD60JBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035531215.208.10314002.22EPA 4048709 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →