CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 11

430 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16430 / 430
EER2 · BTU/Wh11.7–12430 / 430
HSPF2 · BTU/Wh7.8–8.1430 / 430
Cooling capacity · BTU/h39,500–42,000430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600430 / 430
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600430 / 430
COP at 5°F / −15°C1.98–2.42430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-410A (GWP:2088)430 / 430
Compressor stagingTwo-stage430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC48FBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248863915.208.10210002.22EPA 2477407
XAFC48FXXN1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21248287215.207.80212002.20EPA 2477525
XAFC48FBCN1+ furnace: Z8ES100B12LMPS1AHRI reference: 21248289515.207.80212002.20EPA 2477898
XAFC48FBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248282615.208.10210002.22EPA 2479213
XAFD48FBCN1+ furnace: Z9ES120D20SMPS1AHRI reference: 21241558615.208.10208002.24EPA 2481575
XAFD48FBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241616815.208.10210002.24EPA 2481672
XAFC48FBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21241640815.208.10208002.20EPA 2481836
XAFC48FXXN1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21241640315.208.10208002.20EPA 2481917
XAFC48FBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21241599815.207.80206002.18EPA 2481966
XAFC48FXXN1+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21241599315.208.10208002.22EPA 2481971
XAFC48FXXN1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21248863215.208.10210002.22EPA 2482915
XAFC48FXXN1+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21248859915.207.80212002.20EPA 2482924
XAFC48FBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248860615.207.80212002.20EPA 2482929
XAFD48FBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21241612315.208.10212002.20EPA 2483749
XAFC48FXXN1+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21241612815.207.80212002.20EPA 2483754
XAFC48FBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21241613315.207.80212002.20EPA 2484017
XAFC48FXXN1+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 21248867415.208.10208002.20EPA 2484171
XAFC48FBCN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248868115.208.10208002.20EPA 2484177
XAFC48FXXN1+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 21241606315.208.10208002.20EPA 2484288
XAFC48FBCN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21241606815.208.10208002.20EPA 2484292

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →