CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 10

430 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16430 / 430
EER2 · BTU/Wh11.7–12430 / 430
HSPF2 · BTU/Wh7.8–8.1430 / 430
Cooling capacity · BTU/h39,500–42,000430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600430 / 430
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600430 / 430
COP at 5°F / −15°C1.98–2.42430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-410A (GWP:2088)430 / 430
Compressor stagingTwo-stage430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60GBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248256816.008.10212002.30EPA 3991150
XAFD60GXXN1+TXV+ furnace: Z8ES080C16SMPS1AHRI reference: 21247789916.008.10208002.28EPA 3991168
XAFD60GXXN1+TXV+ furnace: Z8ES080C16LMPS1AHRI reference: 21247790416.008.10208002.28EPA 3991171
XAHD60GBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21259431516.008.10220002.34EPA 3991231
XAFD60GXXN1+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21259447516.008.10212002.26EPA 3991313
XAFD60GBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 21259448016.008.10212002.26EPA 3991321
XAFC60GBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 21259466516.008.10212002.24EPA 3991463
XAFC60GBCN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21259469016.008.10210002.28EPA 3991480
XAFD60GXXN1+TXV+ furnace: Z8ET080C16LMPS1AHRI reference: 21259450016.008.10210002.28EPA 3991582
XAFD60GBCN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21259450516.008.10210002.28EPA 3991583
XAFC60GBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21248827715.958.10210002.28EPA 3990902
XAFC60GBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248828715.958.10210002.28EPA 3990906
XAFC48FXXN1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21248280215.208.10210002.22EPA 2476478
XAFD48FBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21241539015.207.80208002.18EPA 2476614
XAHC48FBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21241597815.207.80218002.36EPA 2476693
XAFD48FBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248574515.208.10212002.20EPA 2476749
XAFD48FBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248577315.208.10210002.22EPA 2476977
XAFC48FBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21241622315.208.10210002.22EPA 2477013
XAHD48FBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21241538015.208.10226002.32EPA 2477156
XAFD48FBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247826915.208.10210002.24EPA 2477199

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →