SEER2 range15.5–18.5BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,400–35,200BTU/h

Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 785 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–18.5785 / 785
EER2 · BTU/Wh9–10.5785 / 785
HSPF2 · BTU/Wh8.1–8.5785 / 785
Cooling capacity · BTU/h31,400–35,200785 / 785
Heating capacity at 47°F / 8.3°C · BTU/h31,400–34,800785 / 785
Heating capacity at 17°F / −8.3°C · BTU/h24,600–27,000785 / 785
Heating capacity at 5°F / −15°C · BTU/h22,200–25,000785 / 785
COP at 5°F / −15°C1.8–2.18785 / 785
Equipment / loop typeHP - Split System785 / 785
Refrigerant / source-reported GWPR-410A (GWP:2088)785 / 785
Compressor stagingContinuously variable785 / 785
Connected capabilityNo785 / 785

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC36DXXN1+TXV+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 21138894717.008.10238002.00EPA 2476881 →
XAHC48FBCN1+ furnace: TMLE120C16MP11Cold climate designationAHRI reference: 21139819717.008.50232002.04EPA 2476896 →
XAHB36DXXN1+TXV+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 21138898817.008.10236002.00EPA 2476958 →
XAFC48FXXN1+TXV+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 21138584517.008.50234002.06EPA 2477051 →
XAFC36DBCN1+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21138783517.008.10244002.06EPA 2477093 →
XAFB36DXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 21138832317.008.50238002.04EPA 2477436 →
XAFC48FBCN1+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 21139830017.008.50236002.08EPA 2477439 →
XAFC48FXXN1+TXV+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 21139865917.008.50238002.06EPA 2477450 →
XAHB36DXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 21138814017.008.10234001.98EPA 2477665 →
XAFC48FXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 21139615217.008.10246002.08EPA 2477682 →
XAFC48FBCN1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 21139871917.008.50238002.06EPA 2477851 →
XAHC36DXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21138875317.008.10234002.02EPA 2477914 →
XAHC36DXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21138768517.008.10234002.02EPA 2477992 →
XAFB36DXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 21138830917.008.50238002.04EPA 2478001 →
XAFC48FXXN1+TXV+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21138632817.008.10240002.02EPA 2478028 →
XAHC48FBCN1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 21139864417.008.10232002.02EPA 2478052 →
XAHC48FBCN1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 21139863417.008.10232002.02EPA 2478080 →
XAHB36DXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 21138812617.008.10234001.98EPA 2478103 →
XAFC36DXXN1+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 21139060717.008.10242002.04EPA 2478116 →
XAFD48FXXN1+TXV+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 21139598717.008.50236002.06EPA 2478299 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.