HMH72B341
HMH7 · source records, page 18
785 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 785 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 785 / 785 |
| EER2 · BTU/Wh | 9–10.5 | 785 / 785 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 785 / 785 |
| Cooling capacity · BTU/h | 31,400–35,200 | 785 / 785 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 785 / 785 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 785 / 785 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 785 / 785 |
| COP at 5°F / −15°C | 1.8–2.18 | 785 / 785 |
| Equipment / loop type | HP - Split System | 785 / 785 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 785 / 785 |
| Compressor staging | Continuously variable | 785 / 785 |
| Connected capability | No | 785 / 785 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHB36DBCN1+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 211392268 | 17.00 | 8.10 | 23400 | 2.00 | EPA 2474619 → |
XAFC48FBCN1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 211397020 | 17.00 | 8.50 | 23600 | 2.04 | EPA 2474624 → |
XAHB36DBCN1+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 211392253 | 17.00 | 8.10 | 23400 | 2.00 | EPA 2474632 → |
XAFC48FXXN1+TXV+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 211397005 | 17.00 | 8.50 | 23600 | 2.04 | EPA 2474654 → |
XAFC48FBCN1+ furnace: TM8E100C16MP11Cold climate designationAHRI reference: 211398547 | 17.00 | 8.50 | 23600 | 2.06 | EPA 2474684 → |
XAFC48FXXN1+TXV+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398532 | 17.00 | 8.50 | 23600 | 2.06 | EPA 2474687 → |
XAFD48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398502 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2474693 → |
XAFC48FXXN1+TXV+ furnace: TM8E100C16MP11Cold climate designationAHRI reference: 211398517 | 17.00 | 8.50 | 23600 | 2.06 | EPA 2474710 → |
XAHD48FBCN1+ furnace: TM8Y100C16MP11Cold climate designationAHRI reference: 211396754 | 17.00 | 8.10 | 24000 | 2.04 | EPA 2474712 → |
XAFD48FBCN1+ furnace: TM8E100C16MP11Cold climate designationAHRI reference: 211398488 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2474722 → |
XAHC48FBCN1+ furnace: TM8Y100C16MP11Cold climate designationAHRI reference: 211396807 | 17.00 | 8.10 | 24000 | 2.04 | EPA 2474759 → |
XAHB36DBCN1+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211388160 | 17.00 | 8.10 | 23400 | 1.98 | EPA 2474893 → |
XAFB36DBCN1+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 211390768 | 17.00 | 8.10 | 23600 | 2.02 | EPA 2474972 → |
XAHC48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398454 | 17.00 | 8.50 | 23200 | 2.04 | EPA 2476175 → |
XAHC48FBCN1+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 211398182 | 17.00 | 8.50 | 23200 | 2.04 | EPA 2476205 → |
XAFC48FXXN1+TXV+ furnace: TMLE120C16MP11Cold climate designationAHRI reference: 211398288 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2476225 → |
XAHC36DBCN1+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 211389310 | 17.00 | 8.10 | 24200 | 2.08 | EPA 2476267 → |
XAFC36DXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387814 | 17.00 | 8.10 | 24400 | 2.06 | EPA 2476506 → |
XAFD48FBCN1+ furnace: TMLE120C16MP11Cold climate designationAHRI reference: 211398258 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2476650 → |
XAFC36DXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387805 | 17.00 | 8.10 | 24400 | 2.06 | EPA 2476869 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.