HH860E2S11
LX SERIES · source records, page 9
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218520745 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4642209 → |
CTF60C5CHS2+ furnace: Z8ES120C20LMPS1AHRI reference: 218520741 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4642213 → |
CTF60C5CHS2+ furnace: Z8ES120C20SMPS1AHRI reference: 218520737 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4642217 → |
CTF60C5CHS2+ furnace: Z8ES100C20LMPS1AHRI reference: 218520733 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4642221 → |
CTF60C5CHS2+ furnace: Z8ES100C20SMPS1AHRI reference: 218520729 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4642225 → |
CTF60C5CHS2+JMC17C2SN1AHRI reference: 218520725 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4642229 → |
CTF60C5CHS2+ furnace: Z9ES080C20SMPS1AHRI reference: 218520721 | 19.00 | 8.50 | 39000 | 2.00 | EPA 4642233 → |
CTF60C5CHS2+ furnace: Z9ES100C20SMPS1AHRI reference: 218520717 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4642237 → |
CTF60C5CHS2+ furnace: TM8V100C20MP12AHRI reference: 218520713 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4642241 → |
CTF60C5CHS2+ furnace: TM8V120C20MP12AHRI reference: 218520709 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4642245 → |
CTF60C5CHS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218520705 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4642249 → |
CTF60C5CHS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218520701 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4642253 → |
CTF60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218520697 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4642257 → |
CTF60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218520693 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4642261 → |
CTM60D5CJS2+JMVT20DC2N1AHRI reference: 218521023 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644549 → |
CTM60D5CJS2+JMC20D2SN1AHRI reference: 218521019 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644553 → |
CTM60D5CJS2+ furnace: TP9C120D20MP13AHRI reference: 218521009 | 19.00 | 9.00 | 40000 | 2.00 | EPA 4644559 → |
CTM60D5CJS2+ furnace: TM9V120D20MP12AHRI reference: 218521005 | 19.00 | 9.00 | 40000 | 2.00 | EPA 4644563 → |
CTM60D5CJS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218521001 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644567 → |
CTM60D5CJS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218520997 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4644571 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →