HH860E2S11
LX SERIES · source records, page 10
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60D5CHS2+JMC20D2SN1AHRI reference: 218520993 | 19.00 | 8.50 | 38000 | 2.00 | EPA 4644575 → |
CTM60D5CHS2+JMVT20DC2N1AHRI reference: 218520989 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644579 → |
CTM60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 218520983 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4644585 → |
CTM60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 218520979 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4644589 → |
CTM60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218520975 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644593 → |
CTM60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218520971 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644597 → |
CTM60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 218520967 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4644601 → |
CTM60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 218520963 | 19.00 | 8.50 | 40000 | 2.00 | EPA 4644605 → |
CTM60C5CHS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218520959 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644609 → |
CTM60C5CHS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218520955 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644613 → |
CTM60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218520951 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644617 → |
CTM60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218520947 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644621 → |
CTM60C5CHS2+ furnace: TL9E100C20UH11AHRI reference: 218520943 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4644625 → |
CTM60C5CHS2+ furnace: Z8ES120C20LMPS1AHRI reference: 218520939 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644629 → |
CTM60C5CHS2+ furnace: Z8ES120C20SMPS1AHRI reference: 218520935 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644633 → |
CTM60C5CHS2+JMC17C2SN1AHRI reference: 218520931 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644637 → |
CTM60C5CHS2+JMVT17CC2N1AHRI reference: 218520927 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644641 → |
CTM60C5CHS2+ furnace: Z8ES100C20LMPS1AHRI reference: 218520923 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644645 → |
CTM60C5CHS2+ furnace: Z8ES100C20SMPS1AHRI reference: 218520919 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4644649 → |
CTM60C5CHS2+ furnace: TL8E100C20UH11AHRI reference: 218520915 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4644653 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →