HH860E2S11
LX SERIES · source records, page 16
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60D5XGS1+TXV+ furnace: Z8ES130D20SMPS1Cold climate designationAHRI reference: 214650833 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3477414 → |
CTU60D5XGS1+TXV+ furnace: Z9ES120D20SMPS1Cold climate designationAHRI reference: 214650016 | 18.00 | 9.00 | 34200 | 2.00 | EPA 3477421 → |
CTU60D5XGS1+TXV+ furnace: TM9Y120D20MP11Cold climate designationAHRI reference: 214651822 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3477429 → |
CTM60D5CGS1+JMET18DS2N1Cold climate designationAHRI reference: 214421544 | 18.00 | 9.50 | 33800 | 2.00 | EPA 3477576 → |
CTU60C5XGS1+TXV+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 214809209 | 18.00 | 9.00 | 33600 | 2.00 | EPA 3559911 → |
CTU60C5XGS1+TXV+ furnace: Z8ES100C20SMPS1Cold climate designationAHRI reference: 214809214 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3559918 → |
CTU60C5XGS1+TXV+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 214809219 | 18.00 | 9.00 | 33000 | 2.00 | EPA 3559922 → |
CTU60C5XGS1+TXV+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 214809224 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3559927 → |
CTU60C5XGS1+TXV+ furnace: Z8ES080C16SMPS1Cold climate designationAHRI reference: 214809253 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3559942 → |
CTU60C5XGS1+TXV+ furnace: Z9ES100C20SMPS1Cold climate designationAHRI reference: 214809263 | 18.00 | 9.00 | 34000 | 2.00 | EPA 3559952 → |
CTU60C5XGS1+TXV+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 214809268 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3560003 → |
CTU60C5XGS1+TXV+ furnace: Z9ES080C16SMPS1Cold climate designationAHRI reference: 214809273 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3560008 → |
CTU60C5XGS1+TXV+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 214808986 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3560073 → |
CTU60C5XGS1+TXV+ furnace: TL8E100C20UH11Cold climate designationAHRI reference: 214808991 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3560078 → |
CTU60C5XGS1+JMVT17CC2N1+TXVCold climate designationAHRI reference: 214809001 | 18.00 | 9.00 | 33000 | 2.00 | EPA 3560088 → |
CTU60C5XGS1+JMC17C2SN1+TXVCold climate designationAHRI reference: 214809006 | 18.00 | 9.00 | 33000 | 2.00 | EPA 3560093 → |
CTU60C5XGS1+TXV+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 214809011 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3560098 → |
CTU60C5XGS1+TXV+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 214809016 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3560103 → |
CTU60C5XGS1+TXV+ furnace: Z8ES080C20SMPS1Cold climate designationAHRI reference: 214809140 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3560120 → |
CTU60C5XGS1+TXV+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 214809175 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3560155 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →