HH860E2S11
LX SERIES · source records, page 15
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS1+ furnace: Z8ES080C20SMPS1Cold climate designationAHRI reference: 214584754 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3438218 → |
CTM60C5CGS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 214584684 | 18.00 | 9.00 | 33000 | 2.00 | EPA 3438220 → |
CTF60C5CGS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 214584759 | 18.00 | 9.00 | 33000 | 2.00 | EPA 3438235 → |
CTM60C5CGS1+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 214584564 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3438275 → |
CTM60C5CGS1+ furnace: Z8ES080C20SMPS1Cold climate designationAHRI reference: 214584599 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3438285 → |
CTF60C5CGS1+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 214584604 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3438290 → |
CTF60C5CGS1+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 214584609 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3438295 → |
CTF60C5CGS1+ furnace: Z8ES080C16SMPS1Cold climate designationAHRI reference: 214584614 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3438300 → |
CTM60C5CGS1+ furnace: Z8ES100C20SMPS1Cold climate designationAHRI reference: 214584649 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3438310 → |
CTM60C5CGS1+ furnace: Z9ES100C16SMPS1Cold climate designationAHRI reference: 214609056 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3473747 → |
CTF60C5CGS1+ furnace: Z9ES100C20SMPS1Cold climate designationAHRI reference: 214609061 | 18.00 | 9.00 | 34000 | 2.00 | EPA 3473752 → |
CTM60D5CGS1+ furnace: Z9ES120D20SMPS1Cold climate designationAHRI reference: 214609085 | 18.00 | 9.00 | 34200 | 2.00 | EPA 3473757 → |
CTF60D5CGS1+ furnace: Z9ES120D20SMPS1Cold climate designationAHRI reference: 214609114 | 18.00 | 9.00 | 34200 | 2.00 | EPA 3473768 → |
CTM60C5CGS1+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 214609139 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3473774 → |
CTM60C5CGS1+ furnace: Z9ES080C16SMPS1Cold climate designationAHRI reference: 214609144 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3473779 → |
CTM60C5CGS1+ furnace: Z9ES100C20SMPS1Cold climate designationAHRI reference: 214609168 | 18.00 | 9.00 | 34400 | 2.00 | EPA 3473784 → |
CTF60C5CGS1+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 214609198 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3473793 → |
CTF60C5CGS1+ furnace: Z9ES080C16SMPS1Cold climate designationAHRI reference: 214609203 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3473797 → |
CTU60D5XGS1+TXV+ furnace: TM9V120D20MP12Cold climate designationAHRI reference: 214649777 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3477405 → |
CTU60D5XGS1+TXV+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 214649782 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3477409 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →