HRG1836S1P
HRG18 SERIES · source records, page 2
47 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HRG1836S1P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 47 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.1–19 | 47 / 47 |
| EER2 · BTU/Wh | 11.7–12.3 | 47 / 47 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 47 / 47 |
| Cooling capacity · BTU/h | 23,000–34,600 | 47 / 47 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–34,600 | 47 / 47 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,000–22,400 | 47 / 47 |
| Heating capacity at 5°F / −15°C · BTU/h | 14,300–18,200 | 47 / 47 |
| COP at 5°F / −15°C | 1.85–2.18 | 47 / 47 |
| Equipment / loop type | HP - Split System | 47 / 47 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 47 / 47 |
| Compressor staging | Continuously variable | 47 / 47 |
| Connected capability | No | 47 / 47 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EAH1P30B+H4TXV01+ furnace: GUH96C045B3MAHRI reference: 207071377 | 18.50 | 8.50 | 15300 | 2.03 | EPA 2447530 → |
HCG24V1PAHRI reference: 207071257 | 18.50 | 8.50 | 15400 | 1.88 | EPA 2447605 → |
HCG30V1PAHRI reference: 207071259 | 18.50 | 8.50 | 15200 | 1.98 | EPA 2447606 → |
E*1P23B+H4TXV01+ furnace: GUH92C045B3MAHRI reference: 207071269 | 18.50 | 8.10 | 14600 | 1.92 | EPA 2447616 → |
EA(C,U)1P24B+H4TXV01+ furnace: GUH92C045B3MAHRI reference: 207071289 | 18.50 | 7.80 | 15500 | 1.91 | EPA 2447696 → |
EA(C,U)1P30B+H4TXV01+ furnace: GUH96T045B3MAHRI reference: 207071303 | 18.50 | 8.10 | 14900 | 1.96 | EPA 2447706 → |
EA(C,U)1P30B+H4TXV01+ furnace: GUH92C045B3MAHRI reference: 207071309 | 18.50 | 8.10 | 15100 | 1.96 | EPA 2447712 → |
EA(C,U)1P30B+H4TXV01+ furnace: GUH92C070B3MAHRI reference: 207071311 | 18.50 | 8.10 | 15000 | 1.97 | EPA 2447714 → |
EAC4X24B+ furnace: GUH96C045B3MAHRI reference: 207071337 | 18.00 | 7.80 | 15600 | 1.93 | EPA 2447458 → |
EAC4X24B+ furnace: GUH96C070B3MAHRI reference: 207071339 | 18.00 | 7.80 | 15600 | 1.94 | EPA 2447460 → |
EAC4X30B+ furnace: GUH95C045B3MAHRI reference: 207071353 | 18.00 | 8.10 | 15100 | 1.97 | EPA 2447474 → |
EAH1P30B+H4TXV01+ furnace: GUH96C070B3MAHRI reference: 207071379 | 18.00 | 8.50 | 15300 | 2.03 | EPA 2447533 → |
E*1P23B+H4TXV01+ furnace: GUH96C045B3MAHRI reference: 207071277 | 18.00 | 8.10 | 14600 | 1.90 | EPA 2447619 → |
E*1P23B+H4TXV01+ furnace: GUH96C070B3MAHRI reference: 207071279 | 18.00 | 8.10 | 14600 | 1.90 | EPA 2447621 → |
ED1P30/36B+H4TXV02+ furnace: GDD92C045B3MAHRI reference: 207071233 | 18.00 | 8.10 | 18100 | 2.04 | EPA 2447627 → |
ED1P30/36B+H4TXV02+ furnace: GDD92C070B3MAHRI reference: 207071235 | 18.00 | 8.10 | 18100 | 2.02 | EPA 2447629 → |
ED1P30/36B+H4TXV02+ furnace: GDD96C045B3MAHRI reference: 207071241 | 18.00 | 8.10 | 17900 | 2.04 | EPA 2447631 → |
EA(C,U)1P24B+H4TXV01+ furnace: GUH96C045B3MAHRI reference: 207071297 | 18.00 | 7.80 | 15600 | 1.93 | EPA 2447700 → |
EA(C,U)1P24B+H4TXV01+ furnace: GUH96C070B3MAHRI reference: 207071299 | 18.00 | 7.80 | 15600 | 1.94 | EPA 2447702 → |
HMG24X1PAHRI reference: 207071253 | 17.50 | 8.10 | 14900 | 1.85 | EPA 2447539 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →