HRG1836S1P
HRG18 SERIES
47 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HRG1836S1P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 47 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.1–19 | 47 / 47 |
| EER2 · BTU/Wh | 11.7–12.3 | 47 / 47 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 47 / 47 |
| Cooling capacity · BTU/h | 23,000–34,600 | 47 / 47 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000–34,600 | 47 / 47 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,000–22,400 | 47 / 47 |
| Heating capacity at 5°F / −15°C · BTU/h | 14,300–18,200 | 47 / 47 |
| COP at 5°F / −15°C | 1.85–2.18 | 47 / 47 |
| Equipment / loop type | HP - Split System | 47 / 47 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 47 / 47 |
| Compressor staging | Continuously variable | 47 / 47 |
| Connected capability | No | 47 / 47 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EAC4X24B+ furnace: GUH92C070B3MAHRI reference: 207071331 | 19.00 | 7.80 | 15500 | 1.95 | EPA 2447456 → |
EAC4X30B+ furnace: GUH96T070B3MAHRI reference: 207071345 | 19.00 | 8.10 | 14800 | 1.97 | EPA 2447466 → |
EAH1P30B+H4TXV01+ furnace: GUH96T045B3MAHRI reference: 207071363 | 19.00 | 8.50 | 15000 | 2.03 | EPA 2447520 → |
EAH1P30B+H4TXV01+ furnace: GUH96T070B3MAHRI reference: 207071365 | 19.00 | 8.50 | 14900 | 2.04 | EPA 2447522 → |
EAH1P30B+H4TXV01+ furnace: GUH92C045B3MAHRI reference: 207071369 | 19.00 | 8.50 | 15200 | 2.03 | EPA 2447526 → |
EAH1P30B+H4TXV01+ furnace: GUH92C070B3MAHRI reference: 207071371 | 19.00 | 8.50 | 15100 | 2.04 | EPA 2447528 → |
E*1P23B+H4TXV01+ furnace: GUH96T045B3MAHRI reference: 207071263 | 19.00 | 8.10 | 14300 | 1.89 | EPA 2447610 → |
E*1P23B+H4TXV01+ furnace: GUH96T070B3MAHRI reference: 207071265 | 19.00 | 8.10 | 14300 | 1.91 | EPA 2447611 → |
E*1P23B+H4TXV01+ furnace: GUH92C070B3MAHRI reference: 207071271 | 19.00 | 8.10 | 14500 | 1.92 | EPA 2447617 → |
EA(C,U)1P24B+H4TXV01+ furnace: GUH96T045B3MAHRI reference: 207071283 | 19.00 | 7.80 | 15300 | 1.93 | EPA 2447632 → |
EA(C,U)1P24B+H4TXV01+ furnace: GUH96T070B3MAHRI reference: 207071285 | 19.00 | 7.80 | 15200 | 1.93 | EPA 2447634 → |
EA(C,U)1P24B+H4TXV01+ furnace: GUH92C070B3MAHRI reference: 207071291 | 19.00 | 7.80 | 15500 | 1.95 | EPA 2447698 → |
EA(C,U)1P30B+H4TXV01+ furnace: GUH96T070B3MAHRI reference: 207071305 | 19.00 | 8.10 | 14800 | 1.97 | EPA 2447708 → |
EAC4X24B+ furnace: GUH96T045B3MAHRI reference: 207071323 | 19.00 | 7.80 | 15300 | 1.93 | EPA 2447720 → |
EAC4X24B+ furnace: GUH96T070B3MAHRI reference: 207071325 | 19.00 | 7.80 | 15200 | 1.93 | EPA 2447722 → |
HCG36V1PAHRI reference: 207071025 | 19.00 | 8.50 | 18100 | 2.16 | EPA 2447724 → |
EAC4X24B+ furnace: GUH92C045B3MAHRI reference: 207071329 | 18.50 | 7.80 | 15500 | 1.91 | EPA 2447454 → |
EAC4X30B+ furnace: GUH96T045B3MAHRI reference: 207071343 | 18.50 | 8.10 | 14900 | 1.96 | EPA 2447464 → |
EAC4X30B+ furnace: GUH92C045B3MAHRI reference: 207071349 | 18.50 | 8.10 | 15100 | 1.96 | EPA 2447470 → |
EAC4X30B+ furnace: GUH92C070B3MAHRI reference: 207071351 | 18.50 | 8.10 | 15000 | 1.97 | EPA 2447472 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.