Carrier / AIR-SOURCE HEAT PUMP

GH8TAN536**AA*

2-STAGE 18 SEER HP · source records, page 3

285 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17285 / 285
EER2 · BTU/Wh11.7–13285 / 285
HSPF2 · BTU/Wh7.8–8.5285 / 285
Cooling capacity · BTU/h33,800–38,000285 / 285
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000285 / 285
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200285 / 285
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600285 / 285
COP at 5°F / −15°C1.78–2.48285 / 285
Equipment / loop typeHP - Split System285 / 285
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)285 / 285
Compressor stagingTwo-stage285 / 285
Connected capabilityNo285 / 285

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA4821XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21561951415.507.80177001.78EPA 3946301
CVAMA4821XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21561966915.507.80178001.78EPA 3946361
CVAMA4821XMA*+ furnace: 59TN6C080C21**20AHRI reference: 21561976815.507.80178001.78EPA 3946431
CVAMA4821XMA*+ furnace: GG96VTAB60100C**AHRI reference: 21561984015.507.80178001.78EPA 3946459
CVAMA4821XMA*+ furnace: 59TP6C100V21**20AHRI reference: 21561983915.507.80178001.78EPA 3946461
CVAVA3817XMA*+ furnace: 58SP*B070V17**16AHRI reference: 21562129615.507.80177001.78EPA 3946490
CVAMA4821XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21561985815.507.80176001.80EPA 3946515
CVAMA4921XMA*+ furnace: 58SP*B090V17**16AHRI reference: 21561987115.507.80180001.78EPA 3946527
CVAMA4921XMA*+ furnace: 58TN*B090C17**16AHRI reference: 21561991615.507.80180001.78EPA 3946572
CVAMA4921XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21561993015.507.80178001.82EPA 3946585
CVAMA4921XMA*+ furnace: 58TP*B090V17**16AHRI reference: 21561996015.507.80180001.78EPA 3946616
CVAVA3721XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562091515.507.80177001.80EPA 3946690
CVAVA3721XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562092815.507.80177001.78EPA 3946705
CVAVA3721XMA*+ furnace: 59TN6C080C21**20AHRI reference: 21562115215.507.80178001.78EPA 3946718
CVAVA3721XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562124215.507.80176001.80EPA 3946771
CVAVA3817XMA*+ furnace: 58CU*A040C17**12AHRI reference: 21562125515.507.80178001.80EPA 3946784
CVAVA3721XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562094115.507.80177001.78EPA 3946788
CVAVA3721XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562102315.507.80177001.80EPA 3946809
CVAVA3721XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562105315.507.80178001.78EPA 3946823
CVAVA3817XMA*+ furnace: 58TN*B070C17**16AHRI reference: 21562138815.507.80177001.78EPA 3946912

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →