Carrier / AIR-SOURCE HEAT PUMP

GH8TAN536**AA*

2-STAGE 18 SEER HP · source records, page 2

285 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17285 / 285
EER2 · BTU/Wh11.7–13285 / 285
HSPF2 · BTU/Wh7.8–8.5285 / 285
Cooling capacity · BTU/h33,800–38,000285 / 285
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000285 / 285
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200285 / 285
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600285 / 285
COP at 5°F / −15°C1.78–2.48285 / 285
Equipment / loop typeHP - Split System285 / 285
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)285 / 285
Compressor stagingTwo-stage285 / 285
Connected capabilityNo285 / 285

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563613816.008.10194002.26EPA 3955058
CAA**3721AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563636916.008.10192002.40EPA 3955135
CAA**4321AM*+ furnace: 58SP*B110V21**22AHRI reference: 21563771316.008.10192002.40EPA 3955492
CAA**4321AM*+ furnace: 58SU*B060M17**16AHRI reference: 21563775916.008.10193002.26EPA 3955522
CAA**4321AM*+ furnace: 58SU*B080M21**20AHRI reference: 21563778616.008.50191002.40EPA 3955541
CAA**4321AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563839216.008.10191002.40EPA 3956019
CAA**4321AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563862016.008.10192002.40EPA 3956054
CAA**4821AM*+ furnace: 58SU*B080M21**20AHRI reference: 21563888016.008.10190002.40EPA 3956119
CAA**4821AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563974516.008.10191002.26EPA 3956443
CAA**3721AM*+ furnace: 58CU*B080C21**20AHRI reference: 21572135716.008.00192002.28EPA 3982082
CAA**4321AM*+ furnace: 58CU*B080C21**20AHRI reference: 21572151816.008.00192002.40EPA 3982127
CAA**4821AM*+ furnace: 59TP7A100V21**22AHRI reference: 21572159216.008.00191002.26EPA 3982199
CVAMA4921XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21571629516.008.00179001.90EPA 3997639
CVAVA3817XMA*+ furnace: 58CU*B060C17**16AHRI reference: 21571669716.008.00175001.82EPA 3997657
CVAVA3817XMA*+ furnace: 58CU*B040C17**12AHRI reference: 21571668316.008.00176001.82EPA 3997671
CAA**3721AM*+ furnace: 59TP7A100V21**22AHRI reference: 21571484716.008.50192002.40EPA 3997698
FT5BD3617X*AHRI reference: 21869538916.008.10183002.20EPA 4683438
CAA**4321AM*+ furnace: 59TN6C080C21**20AHRI reference: 21563845915.508.00193002.26EPA 3719670
CVAMA4821XMA*+ furnace: 58CU*A080C21**20AHRI reference: 21561944815.507.80176001.78EPA 3946243
CVAMA4821XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21561950115.507.80177001.78EPA 3946279

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →