Carrier / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 27

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*2412AM*+ furnace: 59TN6C120C24**22AHRI reference: 21564996616.008.00111002.05EPA 3997252 →
CSAH*2412AM*+ furnace: 59TN6C060C17**14AHRI reference: 21564988316.008.00111002.05EPA 3997266 →
CSAH*2412AM*+ furnace: 58TP*B090V21**20AHRI reference: 21564933216.008.00111002.05EPA 3997286 →
CSAH*2412AM*+ furnace: 59TN7A120C24**22AHRI reference: 21571296916.008.00111002.05EPA 3997307 →
CSAH*2412AM*+ furnace: 59TP7A120V24**22AHRI reference: 21571306616.008.00111002.05EPA 3997316 →
CSAH*2412AM*+ furnace: 59TP7A080V21**20AHRI reference: 21571301916.008.00111002.05EPA 3997332 →
CSAH*2412AM*+ furnace: 58TN*B090C17**16AHRI reference: 21564917116.008.00111002.05EPA 3997341 →
CSAH*2412AM*+ furnace: 58TN*B070C17**16AHRI reference: 21564913216.008.00111002.05EPA 3997374 →
CSAH*3012AM*+ furnace: 59MN7C060C21**20AHRI reference: 21565093116.008.00111002.05EPA 3997388 →
CSAH*2412AM*+ furnace: 58TN*B045C17**12AHRI reference: 21564909016.008.00111002.05EPA 3997395 →
CSAH*3012AM*+ furnace: GG96VTAB30040A**AHRI reference: 21565145216.008.00114002.05EPA 3997416 →
CSAH*2412AM*+ furnace: 58SU*B040M17**12AHRI reference: 21564897416.007.80110002.05EPA 3997434 →
CSAH*2412AM*+ furnace: 58SP*B135V24**22AHRI reference: 21564895516.008.00112002.05EPA 3997452 →
CSAH*2412AM*+ furnace: 58SP*B090V21**20AHRI reference: 21564891816.008.00111002.05EPA 3997465 →
CSAH*3012AM*+ furnace: 59TN7A060C17**16AHRI reference: 21571308316.008.00112002.05EPA 3997468 →
CSAH*2412AM*+ furnace: 58SP*B090V17**16AHRI reference: 21564890016.008.00111002.05EPA 3997492 →
CSAH*3012AM*+ furnace: 59MN7C060C17**14AHRI reference: 21565090916.008.00111002.05EPA 3997577 →
CSAH*3012AM*+ furnace: 59TP6C040V14**10AHRI reference: 21565145016.008.00114002.05EPA 3997592 →
CSAH*3012AM*+ furnace: 59SU5B040M17**12AHRI reference: 21565118916.008.00111002.05EPA 3997594 →
CSAH*3012AM*+ furnace: 59SP6B040V14**10AHRI reference: 21565103616.008.00113002.05EPA 3997613 →