Carrier / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 26

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3612AM*+ furnace: 59TN7A120C24**22AHRI reference: 21572122016.007.80110002.08EPA 3982039 →
CSAH*3612AM*+ furnace: 59TP7A100V21**20AHRI reference: 21572123416.007.80110002.08EPA 3982048 →
CSAH*3612AM*+ furnace: 59TP7A100V21**22AHRI reference: 21572125216.007.80109002.10EPA 3982069 →
CSAH*3612AM*+ furnace: 59TN6C040C14**10AHRI reference: 21565280216.008.00112002.05EPA 3996886 →
CSAH*3612AM*+ furnace: 59TP6C060V14**12AHRI reference: 21565297816.008.00111002.05EPA 3996896 →
CSAH*2412AM*+ furnace: OVMAAB036098AHRI reference: 21565023616.007.80111002.00EPA 3996921 →
CSAH*2412AM*+ furnace: 58TN*B135C24**22AHRI reference: 21564923216.008.00111002.05EPA 3996923 →
CSAH*2412AM*+ furnace: 58TN*B090C21**20AHRI reference: 21564919116.008.00111002.05EPA 3996955 →
CSAH*2412AM*+ furnace: 59SP6B080V21**20AHRI reference: 21564967616.008.00111002.05EPA 3996969 →
CSAH*3612AM*+ furnace: 59TP6C040V14**10AHRI reference: 21565292716.008.00112002.05EPA 3997028 →
CSAH*3612AM*+ furnace: GG96VTAB30040A**AHRI reference: 21565292816.008.00112002.05EPA 3997029 →
CSAH*3012AM*+ furnace: 58TN*B045C17**12AHRI reference: 21565054216.008.00111002.05EPA 3997036 →
CSAH*3612AM*+ furnace: 59SP6B060V14**12AHRI reference: 21565255616.008.00111002.05EPA 3997071 →
CSAH*3612AM*+ furnace: 59SP6B040V17**12AHRI reference: 21565253716.008.00112002.05EPA 3997083 →
CSAH*3612AM*+ furnace: 59SP6B040V14**10AHRI reference: 21565251816.008.00112002.05EPA 3997106 →
CSAH*2412AM*+ furnace: 58TP*B090V17**16AHRI reference: 21564931716.008.00111002.05EPA 3997132 →
CSAH*2412AM*+ furnace: 59MN7C060C21**20AHRI reference: 21564947416.008.00111002.05EPA 3997153 →
CSAH*2412AM*+ furnace: 59SU5B040M17**12AHRI reference: 21564973216.007.80112002.00EPA 3997184 →
CSAH*2412AM*+ furnace: 59TP6C080V21**20AHRI reference: 21565011916.008.00111002.05EPA 3997220 →
CSAH*2412AM*+ furnace: 59MN7C060C17**14AHRI reference: 21564945216.008.00111002.05EPA 3997239 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →