37MUHAQ24AA3+KSAIC0701230
Crossover Heat Pump · source records, page 11
557 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 557 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 557 / 557 |
| EER2 · BTU/Wh | 10–11 | 557 / 557 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 557 / 557 |
| Cooling capacity · BTU/h | 22,600–25,000 | 557 / 557 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 557 / 557 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 557 / 557 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 557 / 557 |
| COP at 5°F / −15°C | 1.85–2.06 | 557 / 557 |
| Equipment / loop type | HP - Split System | 557 / 557 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 557 / 557 |
| Compressor staging | Continuously variable | 557 / 557 |
| Connected capability | No | 557 / 557 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3617AM*+ furnace: 59SP6B040V14**10Cold climate designationAHRI reference: 218473564 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625769 → |
CAA**3017AM*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 218473553 | 16.50 | 8.50 | 19700 | 1.90 | EPA 4625780 → |
CAA**3017AM*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 218473550 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4625783 → |
CAA**3017AM*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 218473549 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625784 → |
CAA**3017AM*+ furnace: 59TP6C080V17**16Cold climate designationAHRI reference: 218473548 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4625785 → |
CAA**3017AM*+ furnace: 59TP6C060V17**16Cold climate designationAHRI reference: 218473547 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625786 → |
CAA**3017AM*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 218473546 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4625787 → |
CAA**3017AM*+ furnace: 59SU5B040M17**12Cold climate designationAHRI reference: 218473542 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625791 → |
CAA**3017AM*+ furnace: 59SP6B080V17**16Cold climate designationAHRI reference: 218473541 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4625792 → |
CAA**3017AM*+ furnace: 59SP6B060V17**16Cold climate designationAHRI reference: 218473540 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625793 → |
CAA**3017AM*+ furnace: 59SP6B060V14**12Cold climate designationAHRI reference: 218473539 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4625794 → |
CAA**3014AM*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 218473526 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625807 → |
CAA**3014AM*+ furnace: 59SP6B060V14**12Cold climate designationAHRI reference: 218473524 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625809 → |
CAA**3014AM*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 218473521 | 16.50 | 8.50 | 19400 | 1.88 | EPA 4625812 → |
CAA**3014AM*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 218473519 | 16.50 | 8.50 | 19400 | 1.88 | EPA 4625814 → |
CAA**2517AM*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 218473518 | 16.50 | 9.00 | 19300 | 2.02 | EPA 4625815 → |
CAA**2517AM*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 218473510 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4625823 → |
CAA**2517AM*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 218473509 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4625824 → |
CAA**2517AM*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 218473503 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4625830 → |
CAA**2517AM*+ furnace: 59SP6B040V14**10Cold climate designationAHRI reference: 218473502 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4625831 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.