37MUHAQ24AA3+KSAIC0701230
Crossover Heat Pump · source records, page 10
557 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 557 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 557 / 557 |
| EER2 · BTU/Wh | 10–11 | 557 / 557 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 557 / 557 |
| Cooling capacity · BTU/h | 22,600–25,000 | 557 / 557 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 557 / 557 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 557 / 557 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 557 / 557 |
| COP at 5°F / −15°C | 1.85–2.06 | 557 / 557 |
| Equipment / loop type | HP - Split System | 557 / 557 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 557 / 557 |
| Compressor staging | Continuously variable | 557 / 557 |
| Connected capability | No | 557 / 557 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3721AM*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 218473630 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4625703 → |
CAA**3721AM*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 218473620 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4625713 → |
CAA**3721AM*+ furnace: 58TP*B110V21**22Cold climate designationAHRI reference: 218473619 | 16.50 | 8.50 | 18900 | 1.92 | EPA 4625714 → |
CAA**3721AM*+ furnace: 58TP*B090V21**20Cold climate designationAHRI reference: 218473618 | 16.50 | 9.00 | 19000 | 2.04 | EPA 4625715 → |
CAA**3721AM*+ furnace: 58SP*B090V21**20Cold climate designationAHRI reference: 218473610 | 16.50 | 9.00 | 19000 | 2.04 | EPA 4625723 → |
CAA**3717AM*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 218473607 | 16.50 | 9.00 | 19500 | 2.04 | EPA 4625726 → |
CAA**3717AM*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 218473600 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4625733 → |
CAA**3717AM*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 218473599 | 16.50 | 8.50 | 19200 | 1.92 | EPA 4625734 → |
CAA**3717AM*+ furnace: 59SP6B060V14**12Cold climate designationAHRI reference: 218473593 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4625740 → |
CAA**3717AM*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 218473592 | 16.50 | 8.50 | 19200 | 1.92 | EPA 4625741 → |
CAA**3617AM*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 218473580 | 16.50 | 9.00 | 19700 | 2.02 | EPA 4625753 → |
CAA**3617AM*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 218473576 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4625757 → |
CAA**3617AM*+ furnace: 59TP6C060V17**16Cold climate designationAHRI reference: 218473574 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4625759 → |
CAA**3617AM*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 218473573 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4625760 → |
CAA**3617AM*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 218473572 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4625761 → |
CAA**3617AM*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 218473571 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625762 → |
CAA**3617AM*+ furnace: 59SU5B040M17**12Cold climate designationAHRI reference: 218473569 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4625764 → |
CAA**3617AM*+ furnace: 59SP6B060V17**16Cold climate designationAHRI reference: 218473567 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4625766 → |
CAA**3617AM*+ furnace: 59SP6B060V14**12Cold climate designationAHRI reference: 218473566 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4625767 → |
CAA**3617AM*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 218473565 | 16.50 | 8.50 | 19400 | 1.90 | EPA 4625768 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →