27VPA948A*030*
Performance 19 SEER2 VS HP · source records, page 19
534 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VPA948A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 534 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 534 / 534 |
| EER2 · BTU/Wh | 10–13.5 | 534 / 534 |
| HSPF2 · BTU/Wh | 8.5–10 | 534 / 534 |
| Cooling capacity · BTU/h | 43,500–49,500 | 534 / 534 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 534 / 534 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 534 / 534 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 534 / 534 |
| COP at 5°F / −15°C | 1.95–2.32 | 534 / 534 |
| Equipment / loop type | HP - Split System | 534 / 534 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 534 / 534 |
| Compressor staging | Continuously variable | 534 / 534 |
| Connected capability | No | 534 / 534 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*4812AM*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 217914854 | 15.50 | 8.50 | 36600 | 2.00 | EPA 4531986 → |
CSAH*4812AM*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 217914857 | 15.50 | 8.50 | 36600 | 2.00 | EPA 4531987 → |
CSAH*6012AM*+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217914860 | 15.50 | 9.00 | 36800 | 2.08 | EPA 4531990 → |
CSAH*6012AM*+ furnace: 59TP6C120V24**22Cold climate designationAHRI reference: 217914909 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532333 → |
CSAH*6012AM*+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217914861 | 15.50 | 8.50 | 36800 | 2.08 | EPA 4532357 → |
CSAH*6012AM*+ furnace: 59TP7A120V24**22Cold climate designationAHRI reference: 217914915 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532364 → |
CSAH*6012AM*+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 217914881 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532373 → |
CSAH*6012AM*+ furnace: 59SP6B080V21**20Cold climate designationAHRI reference: 217914889 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532378 → |
CSAH*6012AM*+ furnace: 59SU5B080M21**20Cold climate designationAHRI reference: 217914893 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532381 → |
CSAH*6012AM*+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 217914896 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532383 → |
CSAH*6012AM*+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 217914898 | 15.50 | 9.00 | 36800 | 2.08 | EPA 4532385 → |
CSAH*6012AM*+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 217914900 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532386 → |
CSAH*6012AM*+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 217914902 | 15.50 | 9.00 | 36800 | 2.08 | EPA 4532388 → |
CSAH*6012AM*+ furnace: 59TP6C080V21**20Cold climate designationAHRI reference: 217914907 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532389 → |
CSAH*6012AM*+ furnace: GG96VTAB66120D**Cold climate designationAHRI reference: 217914910 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532391 → |
CSAH*6012AM*+ furnace: 59TP7A080V21**20Cold climate designationAHRI reference: 217914913 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4532392 → |
CVAVA4821XMA*+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 217908028 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4534232 → |
CVAVA4821XMA*+ furnace: 59SP6B100V21**20Cold climate designationAHRI reference: 217908031 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4534235 → |
CVAVA4821XMA*+ furnace: 59SU5B100M21**20Cold climate designationAHRI reference: 217908033 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4534236 → |
CVAVA4821XMA*+ furnace: 59SU5B100M21**22Cold climate designationAHRI reference: 217908034 | 15.50 | 9.00 | 39500 | 2.10 | EPA 4534237 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →