27VPA948A*030*
Performance 19 SEER2 VS HP · source records, page 18
534 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VPA948A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 534 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 534 / 534 |
| EER2 · BTU/Wh | 10–13.5 | 534 / 534 |
| HSPF2 · BTU/Wh | 8.5–10 | 534 / 534 |
| Cooling capacity · BTU/h | 43,500–49,500 | 534 / 534 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 534 / 534 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 534 / 534 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 534 / 534 |
| COP at 5°F / −15°C | 1.95–2.32 | 534 / 534 |
| Equipment / loop type | HP - Split System | 534 / 534 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 534 / 534 |
| Compressor staging | Continuously variable | 534 / 534 |
| Connected capability | No | 534 / 534 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**6024AM*+ furnace: 59SP6B080V21**20Cold climate designationAHRI reference: 217914732 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4531269 → |
CAA**6024AM*+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 217914737 | 15.50 | 9.00 | 37000 | 2.10 | EPA 4531272 → |
CAA**6024AM*+ furnace: 59TP6C080V21**20Cold climate designationAHRI reference: 217914739 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4531273 → |
CAA**6024AM*+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 217914738 | 15.50 | 9.00 | 37000 | 2.10 | EPA 4531274 → |
CAA**6024AM*+ furnace: 59TP7A080V21**20Cold climate designationAHRI reference: 217914745 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4531280 → |
CAA**6124AM*+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 217914808 | 15.50 | 9.00 | 37200 | 2.12 | EPA 4531609 → |
CAA**6124AM*+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 217914811 | 15.50 | 9.00 | 37200 | 2.12 | EPA 4531955 → |
CAA**6124AM*+ furnace: 59TP6C080V21**20Cold climate designationAHRI reference: 217914812 | 15.50 | 9.00 | 37400 | 2.10 | EPA 4531956 → |
CAA**6124AM*+ furnace: 59TP7A080V21**20Cold climate designationAHRI reference: 217914818 | 15.50 | 9.00 | 37400 | 2.10 | EPA 4531963 → |
CSAH*4812AM*+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217914823 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531968 → |
CSAH*4812AM*+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 217914825 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531970 → |
CSAH*4812AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 217914828 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531973 → |
CSAH*4812AM*+ furnace: 58SU*B100M21**20Cold climate designationAHRI reference: 217914830 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531975 → |
CSAH*4812AM*+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 217914835 | 15.50 | 8.50 | 36600 | 2.00 | EPA 4531977 → |
CSAH*4812AM*+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 217914839 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531980 → |
CSAH*4812AM*+ furnace: 59SU5B080M21**20Cold climate designationAHRI reference: 217914844 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531981 → |
CSAH*4812AM*+ furnace: 59SU5B100M21**20Cold climate designationAHRI reference: 217914845 | 15.50 | 8.50 | 36600 | 2.00 | EPA 4531982 → |
CSAH*4812AM*+ furnace: 59SU5B100M21**22Cold climate designationAHRI reference: 217914846 | 15.50 | 8.50 | 36600 | 2.00 | EPA 4531983 → |
CSAH*4812AM*+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 217914847 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531984 → |
CSAH*4812AM*+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 217914849 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4531985 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →