Carrier / AIR-SOURCE HEAT PUMP

27VPA936A*030*

Performance 19 SEER2 VS HP · source records, page 12

497 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for 27VPA936A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 497 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18497 / 497
EER2 · BTU/Wh10.5–13.5497 / 497
HSPF2 · BTU/Wh7.8–9497 / 497
Cooling capacity · BTU/h33,400–37,600497 / 497
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400497 / 497
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600497 / 497
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600497 / 497
COP at 5°F / −15°C1.9–2.18497 / 497
Equipment / loop typeHP - Split System497 / 497
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)497 / 497
Compressor stagingContinuously variable497 / 497
Connected capabilityNo497 / 497

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA4217XMA*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 21790783115.508.50262002.00EPA 4533582
CVAVA4221XMA*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 21790783815.508.50262002.00EPA 4533585
CVAVA4221XMA*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 21790784115.508.50262002.00EPA 4533588
CVAVA4221XMA*+ furnace: 58TN*B070C21**20Cold climate designationAHRI reference: 21790784615.508.50262002.02EPA 4533593
CVAVA4221XMA*+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 21790784815.509.00262002.12EPA 4533595
CVAVA4221XMA*+ furnace: 58TP*B090V17**16Cold climate designationAHRI reference: 21790785115.508.50262002.00EPA 4533598
CVAVA4221XMA*+ furnace: 59SP6B080V21**20Cold climate designationAHRI reference: 21790785815.508.50264002.00EPA 4533601
CVAVA4217XMA*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 21790780615.508.50262002.00EPA 4533630
CAA**4821AM*+ furnace: 58SU*B100M21**20AHRI reference: 21790865515.509.00252002.04EPA 4533744
CAA**4821AM*+ furnace: 58SU*B060M17**16AHRI reference: 21790865315.509.00252002.06EPA 4533745
CAA**4821AM*+ furnace: 58TN*B090C17**16AHRI reference: 21790865915.509.00254002.06EPA 4533753
CAA**4821AM*+ furnace: 58TN*B110C21**20AHRI reference: 21790866115.509.00252002.06EPA 4533754
CAA**4821AM*+ furnace: 58TP*B090V17**16AHRI reference: 21790866315.509.00252002.06EPA 4533755
CAA**4821AM*+ furnace: 58TP*B110V21**22AHRI reference: 21790866515.509.00252002.08EPA 4533757
CAA**4821AM*+ furnace: 58TN*B090C21**20AHRI reference: 21790866015.509.00252002.06EPA 4533758
CAA**4821AM*+ furnace: 59CU5B100C21**22AHRI reference: 21790866815.509.00252002.08EPA 4533760
CAA**4821AM*+ furnace: 59MN7C080C21**20AHRI reference: 21790867215.509.00252002.06EPA 4533761
CAA**4821AM*+ furnace: 59MN7C100C21**22AHRI reference: 21790867315.509.00252002.08EPA 4533762
CAA**4821AM*+ furnace: 59SP6B100V21**20AHRI reference: 21790867715.509.00252002.06EPA 4533764
CAA**4821AM*+ furnace: 59SU5B100M21**20AHRI reference: 21790868115.509.00252002.08EPA 4533765

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →