Carrier / AIR-SOURCE HEAT PUMP

27VPA936A*030*

Performance 19 SEER2 VS HP · source records, page 11

497 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for 27VPA936A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 497 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18497 / 497
EER2 · BTU/Wh10.5–13.5497 / 497
HSPF2 · BTU/Wh7.8–9497 / 497
Cooling capacity · BTU/h33,400–37,600497 / 497
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400497 / 497
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600497 / 497
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600497 / 497
COP at 5°F / −15°C1.9–2.18497 / 497
Equipment / loop typeHP - Split System497 / 497
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)497 / 497
Compressor stagingContinuously variable497 / 497
Connected capabilityNo497 / 497

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**4321AM*+ furnace: 59TN7A080C21**20AHRI reference: 21790862815.509.00248002.08EPA 4532816 →
CAA**4321AM*+ furnace: 59TP6C080V21**20AHRI reference: 21790863415.509.00248002.08EPA 4532819 →
CAA**4321AM*+ furnace: 59TP6C100V21**20AHRI reference: 21790863515.509.00248002.08EPA 4532820 →
CAA**4321AM*+ furnace: GG96VTAB60100C**AHRI reference: 21790863615.509.00248002.08EPA 4532821 →
CAA**4321AM*+ furnace: 59TP7A080V21**20AHRI reference: 21790864015.509.00248002.08EPA 4532824 →
CAA**4321AM*+ furnace: 59TP7A100V21**20AHRI reference: 21790864115.509.00248002.08EPA 4532826 →
CAA**4821AM*+ furnace: 58CU*B040C17**12AHRI reference: 21790864415.509.00252002.06EPA 4533554 →
CAA**4821AM*+ furnace: 58CU*B060C17**16AHRI reference: 21790864515.509.00252002.06EPA 4533555 →
CAA**4821AM*+ furnace: 58CU*B100C21**20AHRI reference: 21790864715.509.00252002.08EPA 4533556 →
CAA**4821AM*+ furnace: 58SP*B090V17**16AHRI reference: 21790864915.509.00252002.06EPA 4533557 →
CAA**4821AM*+ furnace: 58SP*B110V21**22AHRI reference: 21790865115.509.00252002.06EPA 4533560 →
CAA**4821AM*+ furnace: 58SU*B040M17**12AHRI reference: 21790865215.509.00252002.06EPA 4533562 →
CVAVA4217XMA*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 21790780915.508.50260002.00EPA 4533563 →
CVAVA4217XMA*+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 21790781315.508.50262002.00EPA 4533566 →
CVAVA4217XMA*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 21790781515.508.50262002.00EPA 4533568 →
CVAVA4217XMA*+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 21790782015.508.50262002.02EPA 4533571 →
CVAVA4217XMA*+ furnace: 59SP6B080V17**16Cold climate designationAHRI reference: 21790782215.508.50262002.00EPA 4533574 →
CVAVA4217XMA*+ furnace: 59SU5B060M17**16Cold climate designationAHRI reference: 21790782315.508.50262002.00EPA 4533576 →
CVAVA4217XMA*+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 21790782515.508.50260002.02EPA 4533578 →
CVAVA4217XMA*+ furnace: 59TP6C080V17**16Cold climate designationAHRI reference: 21790782915.508.50262002.00EPA 4533580 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →