27VPA924A*030*
Performance 19 SEER2 VS HP · source records, page 38
1,222 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VPA924A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,222 / 1,222 |
| EER2 · BTU/Wh | 11.5–14 | 1,222 / 1,222 |
| HSPF2 · BTU/Wh | 8–10 | 1,222 / 1,222 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,222 / 1,222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,222 / 1,222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,222 / 1,222 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,222 / 1,222 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,222 / 1,222 |
| Equipment / loop type | HP - Split System | 1,222 / 1,222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,222 / 1,222 |
| Compressor staging | Continuously variable | 1,222 / 1,222 |
| Connected capability | No | 1,222 / 1,222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3017AM*+ furnace: 59TP6C060V17**16Cold climate designationAHRI reference: 217934802 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542511 → |
CAA**3017AM*+ furnace: GG96VTAB48060B**Cold climate designationAHRI reference: 217934803 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542512 → |
CAA**3017AM*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 217934804 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542513 → |
CAA**3721AM*+ furnace: OVLAAB036098Cold climate designationAHRI reference: 217934806 | 17.50 | 10.00 | 21400 | 2.00 | EPA 4542524 → |
CVAVA2514XMA*+ furnace: 59SP6B060V14**12Cold climate designationAHRI reference: 217934238 | 17.50 | 8.50 | 21200 | 1.90 | EPA 4542721 → |
CVAVA2514XMA*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 217934241 | 17.50 | 8.50 | 21200 | 1.90 | EPA 4542724 → |
CVAVA2517XMA*+ furnace: 59SP6B040V14**10Cold climate designationAHRI reference: 217934261 | 17.50 | 8.50 | 22000 | 1.90 | EPA 4542745 → |
CVAVA2517XMA*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 217934262 | 17.50 | 8.50 | 21600 | 1.92 | EPA 4542746 → |
CVAVA2517XMA*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 217934274 | 17.50 | 8.50 | 21600 | 1.92 | EPA 4542757 → |
CVAVA3014XMA*+ furnace: 59SP6B060V14**12Cold climate designationAHRI reference: 217934289 | 17.50 | 8.50 | 21400 | 1.90 | EPA 4542772 → |
CVAVA3014XMA*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 217934292 | 17.50 | 8.50 | 21400 | 1.90 | EPA 4542775 → |
CVAVA3017XMA*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 217934313 | 17.50 | 8.50 | 21600 | 1.92 | EPA 4542897 → |
CVAVA3017XMA*+ furnace: 59SP6B040V14**10Cold climate designationAHRI reference: 217934312 | 17.50 | 8.50 | 21600 | 1.92 | EPA 4542898 → |
CVAVA3017XMA*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 217934324 | 17.50 | 8.50 | 21800 | 1.90 | EPA 4542908 → |
CVAVA3017XMA*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 217934325 | 17.50 | 8.50 | 21600 | 1.92 | EPA 4542910 → |
CAA**2417AM*+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217934869 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4543003 → |
CAA**2417AM*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 217934870 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4543004 → |
CAA**2417AM*+ furnace: 58TP*B090V17**16Cold climate designationAHRI reference: 217934871 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4543005 → |
CAA**3017AM*+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 217934872 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4543006 → |
CAA**3017AM*+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217934873 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4543007 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.