| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,222 / 1,222 |
| EER2 · BTU/Wh | 11.5–14 | 1,222 / 1,222 |
| HSPF2 · BTU/Wh | 8–10 | 1,222 / 1,222 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,222 / 1,222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,222 / 1,222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,222 / 1,222 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,222 / 1,222 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,222 / 1,222 |
| Equipment / loop type | HP - Split System | 1,222 / 1,222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,222 / 1,222 |
| Compressor staging | Continuously variable | 1,222 / 1,222 |
| Connected capability | No | 1,222 / 1,222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA3017XMA*+ furnace: OVMAAB036098Cold climate designationAHRI reference: 217934056 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4547551 → |
CVAMA2417XMA*+ furnace: GG96VTAB48060B**Cold climate designationAHRI reference: 217935715 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4547776 → |
CVAMA2417XMA*+ furnace: GG96VTAB48080B**Cold climate designationAHRI reference: 217935731 | 18.00 | 8.50 | 21200 | 1.88 | EPA 4547795 → |
CVAVA2417XMA*+ furnace: GG96VTAB48060B**Cold climate designationAHRI reference: 217939347 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4552423 → |
CVAVA2417XMA*+ furnace: GG96VTAB48080B**Cold climate designationAHRI reference: 217939363 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4552440 → |
FG5ANXB24L*Cold climate designationAHRI reference: 217952501 | 18.00 | 9.50 | 21400 | 1.92 | EPA 4560068 → |
CAA**3721AM*+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 217934725 | 17.50 | 10.00 | 21200 | 1.98 | EPA 4542027 → |
CAA**2414AM*+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217934731 | 17.50 | 9.50 | 21200 | 1.90 | EPA 4542032 → |
CAA**2414AM*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 217934730 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542033 → |
CAA**2414AM*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 217934732 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542034 → |
CAA**2417AM*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 217934733 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542035 → |
CAA**2417AM*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 217934734 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542036 → |
CAA**2517AM*+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217934735 | 17.50 | 10.00 | 21400 | 2.00 | EPA 4542037 → |
CAA**3717AM*+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217934736 | 17.50 | 9.50 | 21400 | 1.92 | EPA 4542038 → |
CVAMA3617XMA*+ furnace: 59SP6B040V14**10Cold climate designationAHRI reference: 217934159 | 17.50 | 8.50 | 22000 | 1.90 | EPA 4542136 → |
CVAMA3617XMA*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 217934160 | 17.50 | 8.50 | 21800 | 1.92 | EPA 4542137 → |
CVAMA3617XMA*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 217934172 | 17.50 | 8.50 | 21800 | 1.92 | EPA 4542146 → |
CVAMA3617XMA*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 217934171 | 17.50 | 8.50 | 21800 | 1.90 | EPA 4542151 → |
CAA**3017AM*+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 217934800 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542509 → |
CAA**3017AM*+ furnace: 59SP6B060V17**16Cold climate designationAHRI reference: 217934801 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4542510 → |