27VNA336A*030*
Infinity 23 VS Heat Pump · source records, page 28
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA336A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 372 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*3612AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 215933144 | 18.50 | 9.00 | 26800 | 1.92 | EPA 3724735 → |
CSAH*3612AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 215933164 | 18.50 | 9.00 | 26200 | 1.92 | EPA 3724755 → |
CAA**3617AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 215939624 | 18.50 | 9.00 | 27600 | 1.92 | EPA 3724997 → |
CSAH*3612AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 215933234 | 18.50 | 9.00 | 26200 | 1.94 | EPA 3725216 → |
CSAH*3612AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 215933244 | 18.50 | 9.00 | 27000 | 1.94 | EPA 3725226 → |
CSAH*3612AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 215939974 | 18.50 | 9.00 | 27200 | 1.92 | EPA 3725436 → |
CSAH*4212AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 215940044 | 18.50 | 9.00 | 27200 | 1.94 | EPA 3725607 → |
CSAH*4212AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 215940054 | 18.50 | 9.00 | 27000 | 1.94 | EPA 3725617 → |
CSAH*4212AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 215933294 | 18.50 | 9.00 | 27400 | 1.94 | EPA 3726428 → |
CSAH*4212AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 215933364 | 18.50 | 9.00 | 27000 | 1.92 | EPA 3726981 → |
CSAH*4212AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 215933394 | 18.50 | 9.00 | 26200 | 1.94 | EPA 3727011 → |
CSAH*4812AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 215940124 | 18.50 | 9.00 | 27200 | 1.92 | EPA 3727130 → |
CSAH*6012AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 215940204 | 18.50 | 9.00 | 26800 | 1.92 | EPA 3727678 → |
CSAH*3612AM*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 215933044 | 18.50 | 9.00 | 26800 | 1.92 | EPA 3727864 → |
CSAH*3612AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 215933054 | 18.50 | 9.00 | 27600 | 1.88 | EPA 3727876 → |
CSAH*4212AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 215933404 | 18.50 | 9.00 | 27000 | 1.92 | EPA 3727945 → |
CSAH*4212AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 215933414 | 18.50 | 9.00 | 27000 | 1.92 | EPA 3727969 → |
CSAH*4212AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 215933464 | 18.50 | 9.00 | 26200 | 1.94 | EPA 3728179 → |
CSAH*3612AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 215933064 | 18.50 | 9.00 | 27200 | 1.92 | EPA 3730304 → |
CSAH*3612AM*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 215933074 | 18.50 | 9.00 | 27000 | 1.94 | EPA 3730315 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.