Carrier / AIR-SOURCE HEAT PUMP

27VNA336A*030*

Infinity 23 VS Heat Pump · source records, page 27

564 published source records · source checked Sep 21, 2026

SEER2 range18–22.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 27VNA336A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–22.5564 / 564
EER2 · BTU/Wh10–13564 / 564
HSPF2 · BTU/Wh8.1–9.5564 / 564
Cooling capacity · BTU/h32,000–36,000564 / 564
Heating capacity at 47°F / 8.3°C · BTU/h33,800–39,500372 / 564
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,800564 / 564
Heating capacity at 5°F / −15°C · BTU/h25,200–29,600564 / 564
COP at 5°F / −15°C1.88–2.1564 / 564
Equipment / loop typeHP - Split System564 / 564
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)564 / 564
Compressor stagingContinuously variable564 / 564
Connected capabilityNo564 / 564

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3612AM*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 21593310419.009.00266001.94EPA 3730235 →
CSAH*3612AM*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 21593311419.009.00266001.94EPA 3730245 →
CSAH*3612AM*+UI+ furnace: 58TN*B070C21**20Cold climate designationAHRI reference: 21593308419.009.00268001.94EPA 3730325 →
CSAH*3612AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 21593309419.009.00268001.94EPA 3730338 →
CSAH*6012AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 21593391419.009.00256001.96EPA 3730342 →
CAA**4821AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21593974419.009.00270001.94EPA 3731431 →
CSAH*3612AM*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 21593993419.009.00268001.94EPA 3732252 →
CSAH*3612AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 21593994419.009.00266001.94EPA 3732262 →
CAA**3617AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 21593205419.009.00278001.92EPA 3732268 →
CAA**3617AM*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 21593206419.009.00272001.92EPA 3732278 →
CAA**3617AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 21593208419.009.00266001.92EPA 3732298 →
CAA**3617AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 21593209419.009.00274001.92EPA 3732308 →
CSAH*4212AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 21593347419.009.00268001.90EPA 3733551 →
CSAH*3612AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21593319419.009.00268001.92EPA 3733666 →
CSAH*3612AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21593320419.009.00266001.92EPA 3733676 →
CSAH*3612AM*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 21593321419.009.00268001.92EPA 3733686 →
CSAH*4812AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 21593354419.009.00270001.90EPA 3733769 →
CSAH*4812AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 21593361419.009.00266001.94EPA 3733779 →
CSAH*6012AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 21593382419.009.00264001.94EPA 3733881 →
CSAH*3612AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 21593313418.509.00272001.92EPA 3724653 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →