27VNA336A*030*
Infinity 23 VS Heat Pump · source records, page 2
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA336A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 372 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA6021XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215935294 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3726001 → |
CVAVA4924XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215936454 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3726053 → |
CVAVA4924XMA*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215936464 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3726063 → |
CVAVA6124XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 215936954 | 22.00 | 8.50 | 28400 | 2.06 | EPA 3726402 → |
CVAVA4924XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215936444 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3726669 → |
CVAMA6021XMA*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215935314 | 22.00 | 8.50 | 28600 | 2.04 | EPA 3726802 → |
CVAMA6024XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215935344 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3726831 → |
CVAMA6024XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215935354 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3726843 → |
CVAMA6024XMA*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215935364 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3727283 → |
CVAMA6024XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215935384 | 22.00 | 8.50 | 28400 | 2.06 | EPA 3727303 → |
CVAVA4924XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215936484 | 22.00 | 8.50 | 28400 | 2.06 | EPA 3727465 → |
CVAVA4924XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215936514 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3727497 → |
CVAVA4924XMA*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 215936524 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3727507 → |
CVAMA6024XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215935414 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3727760 → |
CVAMA6024XMA*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 215935424 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3727770 → |
CVAMA6024XMA*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215935434 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3727779 → |
CVAMA6024XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 215935444 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3727788 → |
CVAMA4421XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215934854 | 22.00 | 8.50 | 28400 | 2.02 | EPA 3728077 → |
CVAMA4421XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215934884 | 22.00 | 8.50 | 28400 | 2.02 | EPA 3728107 → |
CVAVA4224XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215936164 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3728227 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →