27VNA336A*030*
Infinity 23 VS Heat Pump
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA336A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 372 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA6124XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215936924 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3726373 → |
CVAVA6124XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215936934 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3726382 → |
CVAVA6124XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215936944 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3726394 → |
CVAMA6124XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215935454 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3727800 → |
CVAMA6124XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215935464 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3727809 → |
CVAMA6124XMA*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215935474 | 22.50 | 8.50 | 28200 | 2.04 | EPA 3727985 → |
CVAMA6124XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215935484 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3727996 → |
CVAMA4921XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215935114 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3724542 → |
FE5BNBD60L*+UICold climate designationAHRI reference: 215933964 | 22.00 | 9.50 | 25200 | 2.08 | EPA 3724668 → |
CVAVA6024XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215936764 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3724708 → |
CVAVA6024XMA*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215936774 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3724718 → |
CVAVA6024XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215936794 | 22.00 | 8.50 | 28400 | 2.06 | EPA 3724812 → |
CVAVA6121XMA*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 215936874 | 22.00 | 9.00 | 28600 | 2.10 | EPA 3725174 → |
CVAVA6121XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215936884 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3725184 → |
CVAMA4421XMA*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 215934834 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3725320 → |
CVAMA4421XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215934844 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3725330 → |
CVAMA6021XMA*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 215935204 | 22.00 | 8.50 | 28600 | 2.04 | EPA 3725694 → |
CVAMA6021XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215935214 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3725704 → |
CVAMA6021XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215935224 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3725717 → |
CVAMA6021XMA*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215935254 | 22.00 | 8.50 | 28400 | 2.02 | EPA 3725961 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →