27VNA048A*030*
Infinity 20 VS Heat Pump · source records, page 8
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA048A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA6121XMA*+UI+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 215682473 | 19.00 | 9.00 | 36800 | 2.12 | EPA 3977423 → |
CVAVA6121XMA*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 215682493 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3977440 → |
CVAVA6124XMA*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 215682513 | 19.00 | 9.50 | 36800 | 2.10 | EPA 3977468 → |
CVAVA6124XMA*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 215682523 | 19.00 | 9.00 | 36400 | 2.12 | EPA 3977474 → |
CVAVA6124XMA*+UI+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 215682533 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3977483 → |
CVAVA6124XMA*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 215682543 | 19.00 | 9.50 | 36800 | 2.10 | EPA 3977490 → |
FE5BN(B,X)C48L*+UICold climate designationAHRI reference: 215662627 | 18.50 | 9.50 | 33600 | 2.14 | EPA 3967080 → |
CAA**6124AM*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215674484 | 18.50 | 9.00 | 33600 | 2.08 | EPA 3968231 → |
CAA**6124AM*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215674494 | 18.50 | 9.00 | 33600 | 2.08 | EPA 3968236 → |
CAA**6124AM*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215674504 | 18.50 | 9.00 | 33600 | 2.08 | EPA 3968242 → |
CAA**6124AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215674594 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968299 → |
CAA**6124AM*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215674637 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968321 → |
CAA**6124AM*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 215674658 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968328 → |
CAA**6121AM*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215674364 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968611 → |
CAA**6121AM*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215674374 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3968623 → |
CVAMA6021XMA*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 215675823 | 18.50 | 9.00 | 36200 | 2.02 | EPA 3968817 → |
CVAMA6024XMA*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 215675853 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3968848 → |
CVAMA6021XMA*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 215675683 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3968945 → |
CVAMA6021XMA*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 215675703 | 18.50 | 9.00 | 37200 | 2.00 | EPA 3968966 → |
CVAMA4821XMA*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 215675363 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3969034 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →