Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA6124XMA*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 215682043 | 19.00 | 9.00 | 36400 | 2.12 | EPA 3976564 → |
CVAMA6124XMA*+UI+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 215682053 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3976579 → |
CVAMA6124XMA*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 215682063 | 19.00 | 9.50 | 36800 | 2.10 | EPA 3976581 → |
CVAVA4924XMA*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 215682243 | 19.00 | 9.00 | 36200 | 2.12 | EPA 3976612 → |
CVAVA4924XMA*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 215682263 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3976636 → |
CVAVA4924XMA*+UI+ furnace: 59TN7A100C21**22Cold climate designationAHRI reference: 215682273 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3976637 → |
CVAVA4924XMA*+UI+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 215682283 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3976653 → |
CVAVA6021XMA*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 215682293 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3976655 → |
CVAVA6021XMA*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 215682323 | 19.00 | 9.00 | 36400 | 2.12 | EPA 3976826 → |
CVAVA6021XMA*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 215682353 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3976858 → |
CVAVA6021XMA*+UI+ furnace: 59TN7A100C21**22Cold climate designationAHRI reference: 215682363 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3976865 → |
CVAVA6024XMA*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 215682373 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3976873 → |
CVAVA6024XMA*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 215682383 | 19.00 | 9.00 | 36200 | 2.12 | EPA 3976947 → |
CVAVA6024XMA*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 215682403 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3976964 → |
CVAVA6024XMA*+UI+ furnace: 59TN7A100C21**22Cold climate designationAHRI reference: 215682413 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3977367 → |
CVAVA6024XMA*+UI+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 215682423 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3977373 → |
CVAVA6121XMA*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 215682433 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3977386 → |
CVAVA6121XMA*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 215682443 | 19.00 | 9.00 | 36800 | 2.12 | EPA 3977395 → |
CVAVA6121XMA*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 215682453 | 19.00 | 9.00 | 36800 | 2.10 | EPA 3977402 → |
CVAVA6121XMA*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 215682463 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3977414 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.