Carrier / AIR-SOURCE HEAT PUMP

27VNA048A*030*

Infinity 20 VS Heat Pump · source records, page 17

376 published source records · source checked Sep 21, 2026

SEER2 range15.5–19.5BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity43,500–49,000BTU/h

Each efficiency range summarizes published EPA records for 27VNA048A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–19.5376 / 376
EER2 · BTU/Wh9–10.5376 / 376
HSPF2 · BTU/Wh8.5–9.5376 / 376
Cooling capacity · BTU/h43,500–49,000376 / 376
Heating capacity at 47°F / 8.3°C · BTU/h47,000–50,000376 / 376
Heating capacity at 17°F / −8.3°C · BTU/h41,000–47,500376 / 376
Heating capacity at 5°F / −15°C · BTU/h33,000–37,600376 / 376
COP at 5°F / −15°C1.92–2.2376 / 376
Equipment / loop typeHP - Split System376 / 376
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)376 / 376
Compressor stagingContinuously variable376 / 376
Connected capabilityNo376 / 376

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**4821AM*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 21568135317.509.00342002.06EPA 3975810
CAA**6024AM*+UI+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 21568139317.509.00336002.06EPA 3975852
CAA**6121AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21568145317.509.00338002.08EPA 3975908
CAA**6121AM*+UI+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 21568147317.509.00336002.06EPA 3975934
CAA**6121AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21568148317.509.00342002.06EPA 3975948
CAA**4821AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 21567407417.009.00346002.04EPA 3967930
CAA**4821AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 21567401417.009.00350002.02EPA 3967969
CAA**4821AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567409417.009.00346002.04EPA 3968014
CAA**4821AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 21567410417.009.00346002.04EPA 3968055
CAA**6121AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 21567432417.009.00346002.06EPA 3968573
CSAH*6012AM*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 21567513217.008.50336002.08EPA 3968684
CAA**4821AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21568131317.009.00342002.04EPA 3974542
CAA**4821AM*+UI+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 21568133317.009.00340002.04EPA 3975342
CSAH*6012AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21568168317.008.50338002.08EPA 3975407
CSAH*6012AM*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 21568169317.008.50336002.06EPA 3975414
CAA**4821AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21568134317.009.00346002.04EPA 3975804
CSAH*4812AM*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 21567469816.508.50342002.06EPA 3968334
CSAH*4812AM*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 21567484016.508.50342002.06EPA 3968381
CSAH*4812AM*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 21567486016.508.50342002.06EPA 3968385