27VNA048A*030*
Infinity 20 VS Heat Pump · source records, page 16
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA048A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**4821AM*+UI+ furnace: 58TN*B070C21**20Cold climate designationAHRI reference: 215674034 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3967992 → |
CAA**4821AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 215674044 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968007 → |
CAA**4821AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 215674114 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968072 → |
CAA**4821AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215674124 | 17.50 | 9.00 | 34000 | 2.04 | EPA 3968090 → |
CAA**4821AM*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215674144 | 17.50 | 9.00 | 34000 | 2.04 | EPA 3968099 → |
CAA**6024AM*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 215674164 | 17.50 | 9.00 | 33600 | 2.06 | EPA 3968115 → |
CAA**6121AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 215674434 | 17.50 | 9.00 | 33600 | 2.08 | EPA 3968170 → |
CAA**6124AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 215674514 | 17.50 | 9.00 | 33800 | 2.08 | EPA 3968259 → |
CAA**6124AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 215674553 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968279 → |
CAA**6024AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 215674214 | 17.50 | 9.00 | 33600 | 2.08 | EPA 3968441 → |
CAA**6024AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 215674234 | 17.50 | 9.00 | 34000 | 2.06 | EPA 3968462 → |
CAA**6121AM*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 215674314 | 17.50 | 9.00 | 33800 | 2.06 | EPA 3968562 → |
CAA**6121AM*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 215674334 | 17.50 | 9.00 | 34000 | 2.06 | EPA 3968583 → |
CAA**6121AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 215674384 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968637 → |
CAA**6121AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 215674404 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3968655 → |
CVAMA4821XMA*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 215675403 | 17.50 | 9.00 | 37000 | 1.98 | EPA 3969076 → |
CVAVA4821XMA*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 215676133 | 17.50 | 9.00 | 37000 | 1.98 | EPA 3969870 → |
CAA**4821AM*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 215681293 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3974524 → |
CAA**4821AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 215681303 | 17.50 | 9.00 | 34000 | 2.04 | EPA 3974540 → |
CAA**4821AM*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 215681323 | 17.50 | 9.00 | 33800 | 2.06 | EPA 3975333 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →