BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 19

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*6012AM*+ furnace: 83*CB60080C21***AHRI reference: 21571784216.007.80250002.20EPA 4001000 →
CAA**4821AM*+ furnace: 83*CA60080C21***AHRI reference: 21563120715.508.10252002.22EPA 3951992 →
CAA**4821AM*+ furnace: 82*SB60090V21***AHRI reference: 21563124815.508.10250002.20EPA 3952005 →
CAA**4821AM*+ furnace: 88*TB60070C21***AHRI reference: 21563135915.508.10254002.20EPA 3952203 →
CAA**4821AM*+ furnace: 82*TB60090V21***AHRI reference: 21563141715.508.10250002.20EPA 3952316 →
CAA**4821AM*+ furnace: 935CB60080C21***AHRI reference: 21563146515.508.10254002.20EPA 3952349 →
CAA**4821AM*+ furnace: 987MC60080C21***AHRI reference: 21563152115.508.10252002.22EPA 3952377 →
CAA**4821AM*+ furnace: 987MC66100C21***AHRI reference: 21563153515.508.10252002.20EPA 3952392 →
CAA**4821AM*+ furnace: 926SB60080V21***AHRI reference: 21563157515.508.10252002.22EPA 3952407 →
CAA**4821AM*+ furnace: 935SB60080M21***AHRI reference: 21563162015.508.10252002.20EPA 3952417 →
CAA**4821AM*+ furnace: 986TD66100C21***AHRI reference: 21563168615.508.10252002.20EPA 3952485 →
CAA**4821AM*+ furnace: 926TC60100V21***AHRI reference: 21563175815.508.10252002.20EPA 3952500 →
CAA**6024AM*+ furnace: 987MC66100C21***AHRI reference: 21563204815.508.10264002.16EPA 3952634 →
CAA**6024AM*+ furnace: 926SB60080V21***AHRI reference: 21563207615.508.10260002.18EPA 3952666 →
CAA**6024AM*+ furnace: 926SB60100V21***AHRI reference: 21563208915.508.10260002.18EPA 3952679 →
CAA**6024AM*+ furnace: 926SB66120V24***AHRI reference: 21563210215.508.10258002.20EPA 3952691 →
CAA**6024AM*+ furnace: 935SB60100M21***AHRI reference: 21563213415.508.10260002.20EPA 3952723 →
CAA**6121AM*+ furnace: 88*TB48070C17***AHRI reference: 21563244215.508.10262002.16EPA 3952737 →
CAA**6121AM*+ furnace: 82*TB48070V17***AHRI reference: 21563249815.508.10260002.18EPA 3952791 →
CAA**6024AM*+ furnace: 986TD66100C21***AHRI reference: 21563218115.508.10264002.16EPA 3952846 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →