BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 18

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*6012AM*+ furnace: 88*TB66135C24***AHRI reference: 21563421916.008.00250002.25EPA 3954178
CSAH*6012AM*+ furnace: 82*TB60090V21***AHRI reference: 21563424916.008.00250002.25EPA 3954194
CSAH*6012AM*+ furnace: 82*TB66110V21***AHRI reference: 21563426516.008.00250002.25EPA 3954211
CSAH*6012AM*+ furnace: 82*TB66135V24***AHRI reference: 21563428316.008.00250002.25EPA 3954228
CSAH*6012AM*+ furnace: 987MC66120C24***AHRI reference: 21563438916.008.00254002.20EPA 3954251
CSAH*6012AM*+ furnace: 926SB60080V21***AHRI reference: 21563442916.008.00252002.20EPA 3954268
CSAH*6012AM*+ furnace: 926SB60100V21***AHRI reference: 21563444216.008.00252002.20EPA 3954280
CSAH*6012AM*+ furnace: 926SB66120V24***AHRI reference: 21563445516.008.00252002.25EPA 3954290
CAA**6121AM*+ furnace: 83*CB60080C21***AHRI reference: 21572177316.008.00252002.26EPA 3981818
CAA**6121AM*+ furnace: 83*CB60100C21***AHRI reference: 21572178716.008.00254002.25EPA 3981840
CAA**6121AM*+ furnace: 927TA60080V21***AHRI reference: 21572180116.008.00256002.20EPA 3981848
CAA**6121AM*+ furnace: 927TA60100V21***AHRI reference: 21572181716.008.00256002.20EPA 3981871
CAA**4821AM*+ furnace: 927TA66100V21***AHRI reference: 21572173316.008.00248002.24EPA 3982217
CAA**6024AM*+ furnace: 83*CB60080C21***AHRI reference: 21572174616.008.00254002.20EPA 3982231
CAA**6024AM*+ furnace: 927TA66100V21***AHRI reference: 21572176016.008.00254002.22EPA 3982239
CAA**6124AM*+ furnace: 927TA66100V21***AHRI reference: 21572186216.008.00258002.20EPA 3982274
CVAMA6021XMA*+ furnace: 83*CB60100C21***AHRI reference: 21572201916.008.00246002.12EPA 3982434
CSAH*6012AM*+ furnace: 927TA66100V21***AHRI reference: 21571799616.008.00250002.25EPA 4000878
CSAH*6012AM*+ furnace: 987MC66100C21***AHRI reference: 21563437516.008.00252002.25EPA 4000910
CSAH*6012AM*+ furnace: 987MC60080C21***AHRI reference: 21563436116.008.00252002.20EPA 4000924